Swing Door
MPS-122
Setting swing door parameters – "MPS-Diag"
62
10.4.3 Select size of the locking element
Choose the length of the locking bracket via the selection point.
Fig. 31: Select length of the locking bracket
Always select the setting "more than 1.3 m" for swing doors in the
wing version.
10.4.4 Select reset source
This option can be used to specify whether, once power has been
restored, the controller first waits for a pulse at the "manual reset"
pulse or whether it starts to home immediately.
Fig. 32: Select reset source
10.4.5 Stalled behaviour (Behaviour when obstruction detected)
This selection point determines the behaviour of the swing door
when an obstacle is recognised.
Do nothing: There is no reaction.
Reduce force and speed: The locking element continues to
push with a reduced force and speed.
Reverse completely and start anew: The locking element
returns to the original position and starts the movement again at
once.
Reverse slightly and start anew: The locking element swivels
back only a small bit, reverses and swivels on into the original
direction again.
Fig. 33: Stalled behaviour (behaviour when obstruction detected)