Swing Door
MPS-122
Commissioning and settings
47
8.4
Setting the home position and hold-open time via button
Danger of crushing
CAUTION
Danger of crushing!
While the swing door is supplied with voltage,
control commands can move the locking element. If
these movements are made unexpectedly, they
may cause crushing.
– Consider possible movements of the locking
element for all work.
You may set the home position and the hold-open time via a
button. The button is below the cover disc.
→
See page 22, Fig. 3
Fig. 21: Button for setting the home position and hold-open time
8.4.1
Setting the home position
Free movement path
Ensure that the swing door can take up operation unhindered. The
movement path of the locking element must be free.
You may perform homing via the button at the control unit.
1. Push the button. The buzzer emits a signal every time the
button is pushed. After 5 seconds, the buzzer emits a signal at
6 Hz twice.
NOTE!
If you do
not
push the button again within the next
10 seconds, the process will be cancelled. The
buzzer emits a signal at 2 Hz twice and the locking
element swivels back to its original home position.
The original home position remains valid.