9.2.3 DIP switch block S3
DIP S3.x
Function
Description
1 CAN
termination
For the pedestrian pivot barriers MPP, the CAN-bus
comprises the logic control unit MBC-110 and the motor
control unit MMC-120. For both control units, CAN
termination must be activated.
See page 76, chapter 12.4.
OFF: CAN termination deactivated
ON: CAN termination activated
2
(DIP S1.5 and S1.6)
Hold-open time
The hold-open time is set via DIP switches S3.2, S1.5 and
S1.6.
For more information, see page 53, DIP-switch
S1.5 and S1.6.
3
Brake in "Home
position"
Adjust brake function.
Options
OFF: When the blocking element is in the home
position, the brake is not engaged (unlocked).
ON: When the blocking element is in the home position,
the brake is engaged (locked). Once a pulse for a valid
passage is pending, the brake is disengaged.
4 – –
Table 9: DIP switch block S3