Pedestrian Pivot Barrier
MPP-112 / MPP-122 / MPP-132 / MPP-212 / MPP-222
Electrical connection
5817,0016EN / Version 00
41
Electromagnetic interference
NOTICE
Electromagnetic interferences may cause
malfunctions of the pedestrian barrier or
adjacent devices!
The pedestrian barrier is approved for industrial,
residential, commercial a business use. Operation
in other electro-magnetic environmental conditions
may cause interferences or malfunctions.
– Place control lines and mains cables into
separate conduits
– Use cables according to the electrical circuit
plan.
– Only install and apply additional parts approved
by MAGNETIC.
– The electrical and electronically additional parts
must be EMC verified and must not exceed the
indicated EMC limit values.
Personal protective equipment
The following must be worn during all installation work:
Work clothes
Protective gloves
Safety shoes.
8.2 Installing electrical protective devices
The safety installations that are required according to regional and
local regulations must be provided by the customer. Usually these
are:
Residual current device (RCD)
Circuit-breaker
Lockable 2-pole main switch acc. to EN 60947-3.