![Magnetic Autocontrol MPP-112 Скачать руководство пользователя страница 55](http://html1.mh-extra.com/html/magnetic-autocontrol/mpp-112/mpp-112_operating-instructions-manual_3571867055.webp)
Pedestrian Pivot Barrier
MPP-112 / MPP-122 / MPP-132 / MPP-212 / MPP-222
Configuration of pedestrian barrier
5817,0016EN / Version 00
55
DIP S2.x
Function
Description
4
Extended brake time
at the third
vandalism attempt
Switch the function "Extended brake time at the third
vandalism attempt" on and off. The function corresponds to
the function for DIP switch S2.7. The DIP switch S2.7 takes
priority over the DIP switch S2.4.
When the function is switched on, the "Extended brake
time" is active from the third vandalism attempt. The
"Extended brake time" is set via DIP switches S2.5 and
S2.6.
When the blocking element is pushed longer than the set
"Extended brake time" in the third vandalism attempt, the
pedestrian pivot barrier behaves according to the
description for DIP-switch S1.4. The "Extended brake time"
is no longer effective.
For the description "DIP-switch
S1.4", see page 53.
Observe that this function refers to the third vandalism
attempt rather than the third grating.
Options
OFF: The "Extended brake time" is not effective at the
third vandalism attempt.
ON: The "Extended brake time" is effective at the third
vandalism attempt.
The "Extended brake time" is set via DIP switches S2.5 and
S2.6. The "Extended brake time" is effective at the third
vandalism attempt. The DIP switch S2.4 must be set to ON.
Options
DIP S2.5
DIP S2.6
Extended brake
time
OFF OFF 5
s
ON OFF 10
s
OFF ON 15
s
ON ON 30
s
5 and 6
Set extended brake
time
7
Extended brake time
at the first vandalism
attempt
Switch the function "Extended brake time at the first
vandalism attempt" on and off. The function corresponds to
the function for DIP switch S2.4. The DIP switch S2.7 takes
priority over the DIP switch S2.4.
When the function is switched on, the "Extended brake
time" is active from the first vandalism attempt. The
"Extended brake time" is set via DIP switches S2.5 and
S2.6.
If more than one vandalism attempt occurs, the "Extended
brake time" continues to be active.
Options
OFF: The "Extended brake time" is not effective for a
vandalism attempt.
ON: The "Extended brake time" is effective at the first
vandalism attempt.