![Magnetek IMPULSE G Plus Series 4 Скачать руководство пользователя страница 56](http://html1.mh-extra.com/html/magnetek/impulse-g-plus-series-4/impulse-g-plus-series-4_installation-manual_3663700056.webp)
IMPULSE®•G+/VG+ Series 4 Profinet Installation Manual - August 2014
56
LED Operator Display
Fault Name
EF0
External Fault Input from the option.
The alarm function for an external device has been triggered.
Cause
Possible Solution
An external fault is being sent from the
upper controller (PLC)
Remove the cause of the external fault
Reset the external fault input from the PLC device
Problem with the PLC program
Check the program used by the PLC and make the
appropriate corrections.
LED Operator Display
Fault Name
oFA00
Option fault
Option is not properly connected.
Cause
Possible Solution
Non-compatible option connected to the
drive
Connect an option that is compatible with the drive.
LED Operator Display
Fault Name
oFA01
Option Fault
Option is not properly connected.
Cause
Possible Solution
Problem with the connectors between
the drive and option
Turn the power off and check the connectors between the
drive and option.
LED Operator Display
Fault Name
oFA03
Option Fault
Option self-diagnostics error.
Cause
Possible Solution
Option hardware fault
Replace the option.
LED Operator Display
Fault Name
oFA04
Option Fault
Option flash write mode.
Cause
Possible Solution
Option hardware fault
Replace the option.