![Magnetek IMPULSE G Plus Series 4 Скачать руководство пользователя страница 38](http://html1.mh-extra.com/html/magnetek/impulse-g-plus-series-4/impulse-g-plus-series-4_installation-manual_3663700038.webp)
IMPULSE®•G+/VG+ Series 4 Profinet Installation Manual - August 2014
38
0x05
Incorrect data type
Change access with value that does not match the
data type of the parameter
0x06
Setting not permitted (can only be
reset)
Change access with value unequal to 0 when this is
not permitted
0x07
Description element cannot be
changed
Change access to a description element that cannot
be changed
0x09
No description data available
Access to unavailable description (parameter value
is available)
0x0B
No operation priority
Change access rights without rights to change
parameters
0x0F
No text array available
Access to text array that is not available (parameter
value is available)
0x11
Request cannot be executed
because of operating mode
Access is temporarily not possible for reasons that
are not specified in detail
0x14
Value impermissible
Change access with a value that is within limits but is
not permissible for other long term reasons
(parameter with defined single values)
0x15
Response too long
The length of the current response exceeds the
maximum transmittable length
0x16
Parameter address impermissible
Illegal value or value that is not supported for the
attribute, number of elements, parameter number or
sub-index, or a combination
0x17
Illegal format
Write request: Illegal format or format of parameter
data that is not supported
0x18
Number of values inconsistent
Write request: Number of values of parameter data
does not match number of elements at the parameter
address
0x19
DO nonexistent
Request to DO, which does not exist
0x65… 0xFF
Manufacturer-specific
--
0x65
Vendor-specific error
Vendor-specific error
0x66
Request not supported
Request not supported
0x67
Communication error
Request cannot be completed because of
communication error
0x6F
Time-out error
Request aborted due to time-out
0x78
PZD map failure
Parameter cannot be mapped to PZD (size
mismatch or non-existent)
0x79
PZD map failure
Parameter cannot be mapped to PZD (size
mismatch or non-existent)
0x7A
Multiple PZD map
Parameter cannot be mapped to PZD (multiple PZD
write)
0x8C
Set torque mode error
Cannot change mode to TORQUE (frequency is
used)
0x90
Illegal Request ID
The request ID of the response is illegal
Error
Meaning
Used at