background image

Flex Pro Tethered Controller Instruction Manual 

April 2019 

Page 

2

 of 

24

 

SERVICE INFORMATION 

 
Your New Remote Control System 

 

Thank you for your purchase of Magnetek’s Flex Pro Tethered Controller.  Without a doubt, our Flex Pro 

systems are the ultimate solution for providing precise, undeterred, and safe control of your material. 

 

If your product ever needs modification or service, please contact one of our representatives at the 

following locations: 

 
 

U.S. Service Information 

For questions regarding service or technical information contact: 
1-866-MAG-SERV 
(1-866-624-7378) 
 
International Service 
 
262-783-3500 

 

World Headquarters: 

 
Magnetek, Inc.  
N49 W13650 Campbell Drive 
Menomonee Falls, WI 53051 
 

Telephone:

  

800-288-8178 

Website

:  

www.magnetek.com 

E-mail:

   

[email protected] 

 

Fax Numbers: 

 

Main:

    

 800-298-3503 

Sales:

    

 262-783-3510 

Service:

  

 262-783-3508 

 

 
Canada Service Information: 

161 Orenda Road  
Unit 1  
Brampton, Ontario  
L6W 1W3 Canada  
Phone: 800-792-7253  
Fax: 905-828-5707 
416-424-7617 (24/7 Service pager)  
 

EU Market Contact: 

Brian Preston 
Magnetek (UK) Ltd. 
Unit 3 Bedford Business Centre 
Mile Road 
Bedford, MK42 9TW UK 
Phone: +44-1234-349191 

©2019 MAGNETEK 

All rights reserved. This notice applies to all copyrighted materials included with this product, including, 
but not limited to, this manual and software embodied within the product. This manual is intended for the 
sole use of the person(s) to whom it was provided, and any unauthorized distribution of the manual or 
dispersal of its contents is strictly forbidden. This manual may not be reproduced in whole or in part by 
any means whatsoever without the expressed written permission of MAGNETEK.  

Содержание Flex Pro Series

Страница 1: ...Flex Pro Tethered Controller Remote Control Equipment Instruction Manual 198 00132 R05 April 2019 Copyright 2019 Magnetek...

Страница 2: ...e www magnetek com E mail mhcustomerservice magnetek com Fax Numbers Main 800 298 3503 Sales 262 783 3510 Service 262 783 3508 Canada Service Information 161 Orenda Road Unit 1 Brampton Ontario L6W 1W...

Страница 3: ...IC SYSTEM WARNINGS 9 4 GENERAL CONTROLLER INFORMATION 10 4 1 EXTERNAL ILLUSTRATION Pro 12 Configuration 10 4 2 INTERNAL ILLUSTRATION Pro 12 Configuration 11 4 3 TYPES OF BUTTONS 12 4 4 ADJUSTABLE SPEE...

Страница 4: ...nufacturers of the equipment where the radio system is used Plant safety rules and procedures of the employers and the owners of facilities where the Magnetek Products are being used Regulations issue...

Страница 5: ...D code no repeats Advanced controls The Flex system utilizes advanced microprocessor controls with 16 bit CRC which provides ultra fast safe precise and error free encoding and decoding Unique I CHIP...

Страница 6: ...l operating or maintenance procedure practice etc which if not strictly observed could result in damage to or destruction of equipment or loss of functional effectiveness Cautions are highlighted as s...

Страница 7: ...EQUIPMENT FAILURE TO FOLLOW THESE WARNINGS COULD RESULT IN SERIOUS INJURY OR DEATH AND DAMAGE TO EQUIPMENT 3 1 GENERAL Radio controlled equipment operates in several directions Quite frequently the eq...

Страница 8: ...ons test the transmitter emergency stop and all warning devices prior to operation testing should be done on each shift without a load be thoroughly trained and knowledgeable in proper and safe operat...

Страница 9: ...nit and the controller unit should always be placed there when not in use This precaution will help prevent unauthorized people from operating the material handling equipment Spare controllers should...

Страница 10: ...y Stop Button 6 Push Button 6 SC Strap Ring S Removable Power Key Switch 7 Push Button 7 SN System Information 1 Push Button 1 8 Push Button 8 CC CAN Connector 2 Push Button 2 9 Push Button 9 MN Crane...

Страница 11: ...pril 2019 Page 11 of 24 4 2 INTERNAL ILLUSTRATION Pro 12 Configuration Figure 3 Figure 4 1 Encoder Board 5 I CHIP 2 CAN Module 6 Dip Switch 3 Status LED Display 7 CAN Connector 4 Function LED Displays...

Страница 12: ...em Please consult the factory for more information 4 4 ADJUSTABLE SPEED CONTROL The proportional buttons normally operate on a scale from 0 100 but can also be scaled down to operate linearly from 0 7...

Страница 13: ...er to define a time after which if no buttons on the controller are pressed the Flex Pro tethered controller will send an OFF command to the equipment and power down To restart the user must turn the...

Страница 14: ...ller has an input voltage range of 7 0 36VDC For applications that operate at voltages above 36VDC a voltage regulator will need to be installed to regulate the voltage to a value that is accepted by...

Страница 15: ...Flex Pro Tethered Controller Instruction Manual April 2019 Page 15 of 24 6 3 CAN CONNECTOR PINOUT...

Страница 16: ...hered Controller Instruction Manual April 2019 Page 16 of 24 6 4 J9139 PROTOCOL The standard J1939 messages that the Flex Pro tethered controller transmits are shown below For custom messaging consult...

Страница 17: ...Flex Pro Tethered Controller Instruction Manual April 2019 Page 17 of 24...

Страница 18: ...Nopen 8NiP DigiPMl InpuP 3 ByPe 3 7 6 D 4 3 2 1 0 CANopen 8NiP DigiPMl InpuP 4 ByPe 4 7 6 D 4 3 2 1 0 CANopen 8NiP DigiPMl InpuP D ByPe D 7 6 D 4 3 2 1 0 CANopen 8NiP DigiPMl InpuP 6 ByPe 6 7 6 D 4 3...

Страница 19: ...AnMlog InpuP 4 CANopen 16NiP AnMlog InpuP 2 CANopen 16NiP AnMlog InpuP 1 Values Button1 0 250 Button2 0 250 Button3 0 250 Button4 0 250 Transmit PDO 3 CANopen 16bit signed analog Inputs 5 8 Magnetek...

Страница 20: ...8 CANopen 16NiP AnMlog InpuP 12 CANopen 16NiP AnMlog InpuP 9 CANopen 16NiP AnMlog InpuP 10 CANopen 16NiP AnMlog InpuP 11 Values Button9 0 250 Button10 0 250 Button11 0 250 Button12 0 250 Configure He...

Страница 21: ...ontroller handset and rotate it clockwise to the On position Figure 10 Figure 11 3 After turning on the controller power check the Status LED on the controller handset for any sign of system irregular...

Страница 22: ...sition Status LED becomes a solid red for four seconds This will disconnect the controller power and the receiver E Stop altogether Turn it further counter clockwise to release the key 7 2 STATUS LIGH...

Страница 23: ...rior to turning on the controller power switch make sure that the red emergency stop button is elevated Improper startup procedure Redo the startup procedure by holding the power key at START position...

Страница 24: ...Flex Pro Tethered Controller Instruction Manual April 2019 Page 24 of 24 8 DECLARATION OF CONFORMITY...

Отзывы: