6 SETUP
6.1 INSTALLATION OF TETHERED CONTROLLER CABLE
The tethered controller cable is attached to the CAN connector on the controller by lining up the alignment
groove and inserting the plug into the CAN connector receptacle. Twist the locking ring on the CAN plug
clockwise to tighten it down and prevent accidental disengagement.
6.2 UNIT POWER
Section 6.3 shows the connections to provide power to the unit. The Flex Pro tethered controller has an
input voltage range of 7.0 - 36VDC. For applications that operate at voltages above 36VDC, a voltage
regulator will need to be installed to regulate the voltage to a value that is accepted by the Flex Pro
tethered controller.
When connecting the Flex Pro tethered controller to a Magnetek receiver, the receiver does not provide
power to the tethered controller. As such, the tethered controller will need to be wired to another power
source. Typically Magnetek will provide a cable with flying leads that is used to wire the tethered
controller to the receiver. The power and ground portions of this cable will need to be connected to an
external power source for the tethered controller to properly operate.