97
(44) Index <5A10 hex to 5A11 hex>: I/O Module 1 and 2
Parameter Settings
Sub
Index
Contents
Size
Access PDO
map
Setting range
(default setting)
0
Number of
Entries
1Byte
(U8)
RO
Not
possible
02 hex
(02 hex)
1
Input Terminal
Function
Setting
2Byte
(U16)
RW
Not
possible
0000 hex to FFFF hex *1
(FFXX hex)
XX = 00: Input terminal bit 0
XX = 01: Input terminal bit 1
to
XX = 07: Input terminal bit 7
2
Output
Terminal
Function
Setting
2Byte
(U16)
RW
Not
possible
0000 hex to FFFF hex *1
(FFXX hex)
XX = 00: Output terminal bit 0
XX = 01: Output terminal bit 1
to
XX = 07: Output terminal bit 7
Indexes 5A10 hex and 5A11 hex are respectively the I/O module 1 and
I/O module 2 parameter settings.
Sub-index 1 sets the input terminal function.
Sub-index 2 sets the output terminal function.
*1 The details of each parameter setting are described below.
①
Input Terminal Function Setting
Input Terminal Function Setting is a 2-byte parameter setting. The
details are shown below.
Offset
Contents
+00
Input terminal number
00 hex: Input terminal bit 0
01 hex: Input terminal bit 1
02 hex: Input terminal bit 2
03 hex: Input terminal bit 3
04 hex: Input terminal bit 4
05 hex: Input terminal bit 5
06 hex: Input terminal bit 6
07 hex: Input terminal bit 7
+01
Input terminal function
00 hex: Addr0: Address bit 0
01 hex: Addr1: Address bit 1
02 hex: Addr2: Address bit 2
Содержание MG80-EC
Страница 2: ...MG80 EC...