18
4.
Specifications
Interface specifications
Item
Specifications
Switch and
Indication
Switch
Node address setting
Setting switch×2 pcs. (Hexadecimal output 8bit)
Setting
value
0x00
Setting mode
IP address is fixed to 192.168.100.1
0x01
to
0xFF
Operates in Operation mode.
The node address is the setting value converted
to decimal notation. However, when 0xFF is set,
the node address is the value written in the
EEPROM inside the MG80-EC.
For the method of writing the node address
value, refer to the manual of the EtherCAT
master unit.
Indication LED lamp status
Refer to 4.2 LED indicator
Communi-
cation I/F
LAN connector
RJ-45×2
(
100BASE-TX
)
Shielded cable.
EtherCAT
communication
・
Transmits the measurement values, error information, and
calculation results to the host device.
・
Receives instructions such as operation parameter changes
from the host device.
・
The communication standard is the EtherCAT standard.
TCP/IP communication
・
When the node address setting switch is set to “0x00,” the
IP address is fixed to 192.168.100.1 and the mode becomes
the Setting mode for communication by TCP/IP.
In Setting mode, the operation parameters and IP address
can be set using the “Setting application for Windows PC.”
Power
FG ×1
+V ×1
0V ×1
Terminal×1
(3 pole)
All modules and measuring units connected to MG80-EC are
supplied from this power supply terminal.