66
(3) Index <1C11 hex>: Sync Manager 1 PDO Assignment
Sub
Index
Contents
Size
Access PDO
map
Setting range
(default setting)
0
Number of
Assigned PDOs
1Byte
(U8)
RO
Not
possible
-
(00 hex)
Gives the number of PDO mappings used by the sync manager.
The mailbox transmit sync manager does not have PDOs.
(4) Index <1C12 hex>: Sync Manager 2 PDO Assignment
Sub
Index
Contents
Size
Access PDO
map
Setting range
(default setting)
0
Number of
Assigned RxPDOs
1Byte
(U8)
RW
*1
Not
possible
00 hex to 11 hex
(11 hex)
1 to
17
RxPDO Mapping
Assignment 1 to
17
2Byte
(U16)
RW
*1
Not
possible
1600 hex to 17FF hex
(1600 hex to 1610 hex)
*1 “RO” is set if there is no RxPDO.
Gives the RxPDO used by the sync manager.
(5) Index <1C13 hex>: Sync Manager 3 PDO Assignment
Sub
Index
Contents
Size
Access PDO
map
Setting range
(default setting)
0
Number of
Assigned TxPDOs
1Byte
(U8)
RW
*2
Not
possible
00 hex to 46 hex
(46 hex)
1 to
17
TxPDO Mapping
Assignment 1 to
70
2Byte
(U16)
RW
*2
Not
possible
1A00 hex to 1BFF hex
(1B00 hex to 1B45 hex)
*2 “RO” is set if there is no TxPDO.
Gives the TxPDO used by the sync manager.
[Precaution]
A maximum of 350 bytes of PDOs can be assigned for the MG80-EC.
Do not assign more than 350 bytes of PDOs.
Содержание MG80-EC