40
8.
Appendix
Operation Parameters
The operation parameters used in each function are recorded in the internal
memory, and operations such as calculation processing are performed in
accordance with those operation parameters.
Operation parameters are changed in Operation mode by rewriting the object
setting values of the applicable parameters via SDO communications from the
host device.
(For details of objects, refer to “8.2 Object Dictionary Structure.”)
Parameters can also be changed in Setting mode by using the dedicated software.
The details of the operation parameters are shown below.
Item
Set value
Default
Measuring
unit
settings
Measuring
unit 1 to
Measuring
unit 16
Sign
00
Positive direction
00
01
Minus direction
Input Resolution
01
0.1um
01
02
0.5um
03
1.0um
04
2.0um
05
5.0um
06
10.0um
Reference point
00
OFF
00
01
ON
Reference point
position clear
00
-
00
01
Clears the reference point position.
Axis
Calculation
Frame A
to
Frame P
1st sign
00
Plus sign
00
01
Minus sign
Main axis No.
00
Measuring unit 1 value
Same value as
frame number
01
Measuring unit 2 value
02
Measuring unit 3 value
03
Measuring unit 4 value
04
Measuring unit 5 value
05
Measuring unit 6 value
06
Measuring unit 7 value
07
Measuring unit 8 value
08
Measuring unit 9 value
09
Measuring unit 10 value
0A
Measuring unit 11 value
0B
Measuring unit 12 value
0C
Measuring unit 13 value
0D
Measuring unit 14 value
0E
Measuring unit 15 value
0F
Measuring unit 16 value
2nd sign
00
Plus sign
FF
01
Minus sign
FF
No reference axis