60
(26) Index <1AB8, 1AB9, 1ABB, 1ABC hex>: 185th, 186th, 188th and 189th TxPDO
Mapping
Sub
Index
Contents
Size
Access PDO
map
Setting range
(default setting)
0
Number of
Objects
1Byte
(U8)
RO
Not
possible
-
(01 hex)
1
PDO entry 1
4Byte
(U32)
RO
Possible
-
(4609 0120 hex
4689 0120 hex
4709 0120 hex
4789 0120 hex)
Gives the 185th, 186th, 188th and 189th TxPDO mapping for the MG50.
(27) Index <1B00 hex to 1B0F hex>: 257th TxPDO Mapping to 272nd TxPDO Mapping
Sub
Index
Contents
Size
Access PDO
map
Setting range
(default setting)
0
Number of
Objects
1Byte
(U8)
RO
Not
possible
-
(01 hex)
1
PDO entry 1
4Byte
(U32)
RO
Possible
-
(5800 0120 hex
5801 0120 hex
5802 0120 hex
to
580E 0120 hex
580F 0120 hex)
Gives the 257th to 272nd TxPDO mapping for the MG80.
(28) Index <1B10 hex>: 273rd TxPDO Mapping
Sub
Index
Contents
Size
Access PDO
map
Setting range
(default setting)
0
Number of
Objects
1Byte
(U8)
RO
Not
possible
-
(0A hex)
1 to
10
PDO entry 1 to 10 4Byte
(U32)
RO
Possible
-
(5810 0101 hex
5810 0201 hex
5810 0301 hex
to
5810 0901 hex
5810 0A01 hex)
Gives the 273rd TxPDO mapping for the MG80.