26 (E)
6.3.4. Build
1.
Select “Project”
→
“Build Configuration” from the menu.
Fig 6-19
FieldbusDESIGNER -- Build -- No.1
2.
After build is complete, check that an error is not output in the “Output” pane.
Fig 6-20
FieldbusDESIGNER -- Build -- No.2
3.
The files generated by build are located in the “Output” folder below the folder
where the project file is located.
●
EthernetIP_CPU1.L5K
This file is a L5K file for X20BC0088
.
This file is needed when using an Allen-Bradley PLC.
●
EthernetIP_CPU1_IF1_ST1.eds
This file is an EDS file (Electronic Data Sheet) for X20BC0088.
This file is needed when using a PLC other than an Allen-Bradley PLC.
●
EthernetIP_CPU1.txt
This text file describes information related to the X20BC0088 configuration
data.
This file is needed to check the I/O data address map of “EthernetIP_CPU1_
IF1_ST1.eds”.
●
EthernetIP_CPU1_IF1_ST1_std.bin
This file is a configuration file (binary file) for X20BC0088.
It can be downloaded directly by using the X20BC0088 Web server function.