Magma
EB3600-AB | Chapter 2 Hardware Installation
48
Two Solid Green LEDs (3.3V) are illuminated on both backplanes when the power cable is connected. This
signifies the unit is on “standby mode.
Power ON the expansion unit
Press the power button on the front switch to power up the EB3600-AB-P unit. Turn on the expansion chassis
first before powering ON the host computer.
Check your installation
before
powering up expansion chassis for the first time. Although the power supply
has an
over voltage protection device built into it
, it may not "trip" in time to fully protect a device that has
been improperly connected, or whose power cable has been damaged.
You must apply power to the expansion chassis BEFORE you power up your computer. This will allow the
higher numbered buses in the bus hierarchy to be at a stable state when the host computer issues its
master power-on bus reset.
Each power supply has individual power LEDs to indicate its power status. The power supply has no power
switch that you can flip ON and OFF. Once the expansion unit (power cable) is plugged into an electrical
outlet the entire system is ready to be powered up through the main power switch (push button) located
on the front panel.
Green means the power supply is ON. Amber or orange, the power supply is standby mode.
Содержание EB3600-AB
Страница 1: ...EB3600 AB User Manual PCIe to PCIe Expansion MODEL EB3600 AB...
Страница 17: ...Magma EB3600 AB Chapter 1 Introduction 17...
Страница 42: ...Magma EB3600 AB Chapter 2 Hardware Installation 42...
Страница 66: ...Magma EB3600 AB Chapter 4 General Technical Information 66...
Страница 67: ...Magma EB3600 AB Chapter 4 General Technical Information 67...
Страница 68: ...Magma EB3600 AB Chapter 4 General Technical Information 68...
Страница 124: ...Magma EB3600 AB Chapter 7 Rack Slide Installation 124...
Страница 143: ...Manual Part Number 09 09957 02 REV C...