Magma
EB3600-AB | Chapter 5 Management Console I/O Manager
104
Servicing the Side A or Side B
You can service one side of the unit without power interruption of the other side of the unit.
Example of performing service: removing or replacing a PCIe card, replacing Interface card, or swapping
out a power supply.
Viewing the expansion chassis from the back. SIDE A is on your Left, SIDE B is in your Right
Viewing the expansion chassis from the front. SIDE A is on your Right, SIDE B is on your Left.
Turning OFF 3.3v when servicing the chassis
Allows you to turn off 3.3v power on side A and B. The left side is A and right is B from back of chassis.
The only reason to turn this off is to service the chassis if A or B server goes down and you need to replace a
GPU, you need to disable 3.3 v standby power to service chassis via GUI. Once disabled you will need to
enable 3.3v standby to turn on the side A or B otherwise when you turn on your host, host turn on will not
work. This is enabled by default.
SIDE A= Turn A Aux Power Off
SIDE B = Turn B Aux Power Off
Содержание EB3600-AB
Страница 1: ...EB3600 AB User Manual PCIe to PCIe Expansion MODEL EB3600 AB...
Страница 17: ...Magma EB3600 AB Chapter 1 Introduction 17...
Страница 42: ...Magma EB3600 AB Chapter 2 Hardware Installation 42...
Страница 66: ...Magma EB3600 AB Chapter 4 General Technical Information 66...
Страница 67: ...Magma EB3600 AB Chapter 4 General Technical Information 67...
Страница 68: ...Magma EB3600 AB Chapter 4 General Technical Information 68...
Страница 124: ...Magma EB3600 AB Chapter 7 Rack Slide Installation 124...
Страница 143: ...Manual Part Number 09 09957 02 REV C...