EN
124
Type
Barines 30 l
HB Art #
6772531 / 6808916
Nominal voltage
220-240 V~
Nominal frequency
50 Hz
Rated power input
540 W
Degree of protection
IPX1
Permissible operation pressure (high/ low) 2.8/ 0.8 Mpa
Max. allowable pressure (high/ low)
3.8/ 1.3 Mpa
Weight net/ gross
17.5 kg/ 19 kg
Capacity per day
30 l (30 °C / 80% RH)
Water tank capacity
5 l
Operating temperature
5-32 °C
Refrigerant
R290/ 70g
Application floor area
25-30 m
2
Noise
46 dB(A)
Dimension (W x H x D)
343 x 512 x 240 mm
Technical Data
Replacement Parts
Warning!
Replacement parts
must conform with the re-
quirements specified by the man-
ufacturer. Therefore use original
replacement parts only or spare
parts authorised by the manufac-
turer.
In case of service requests or spare
parts, please contact your local
HORNBACH store or write an email
Noise
The values given in these instruc-
tions have been measured in ac-
cordance with a standardized
measurement procedure and can
be used to compare appliances.
It may be used for a preliminary as-
sessment of exposure.
Storage
Clean the appliance, the water tank
and the grilles before covering it
with plastic foil.
Store the appliance in a dry and
frost-proof place. Ensure to store
the appliance in a room with a di-
mension of min. 25 - 30 m
3
. The
appliance shall only be stored in
rooms without permanent ignition
source.
EN
125
Problem
Solution
The appliance doesn't
start.
-
Check if the power supply cord is inserted cor-
rectly.
-
Environmental temperature is too high or too
low.
-
The dehumidifier has reached the preset humid-
ity setting.
-
The water tank is not inserted correctly.
The appliance doesn't
dry the air as expected.
-
Time was too short.
-
Make sure the appliance is free from obstacles.
-
The humidity setting isn't set low enough.
-
Check if all windows and other openings are
closed.
-
The room temperature is too low (lower than
5 °C).
-
There is an appliance which emits water vapour
Loud sounds from the
appliance.
-
The appliance stands tilted and not upright.
-
The floor is not flat.
-
Filter is blocked. Clean filter.
Ice appears on the spools
-
This is a normal process. The appliance has an
automatic defrost.
Water on the floor
-
The hose is loose or leaky.
-
The water tank is in use, but the rubber plug at
the rear outlet is removed.
In case of service requests please contact your local HORNBACH store or
write an email to: [email protected]
Troubleshooting
Code
Meaning
Solution
E2
Temperature sensor is defec-
tive
Disconnect and connect the power
supply cord. If error still occurs, con-
tact your HORNBACH store.
P1
Appliance is defrosting
Code will disappear automatically
when the appliance has defrosted.
FL
Water tank is full or not insert-
ed correctly
Empty the water tank and insert it
correctly into the appliance.
LO/HI
The ambient temperature is
too low/high
It´s a normal phenomenon.
Error and safety codes