background image

MACON

Multi-Function Water To Water Heat Pump

1.2  The unit can be installed  inside  floor or any other inside convenient place and reliable  load -bearing.
1.3  The installation position can hold the unit without noise and shake.
1.4  No sunlight to the unit. 
1.5  The installation position will not be affected by garbage, oil and mist.
1.6  The unit will be damaged under the condition with oil(engine oil), salt(sea area)  and sulfide air(near 
        thermal spring and refining factory). 

6

6

2.    water  tank(hot water tank and buffer water tank) install location select

2

.1  The water tank can be installed in the outdoor with heat pump outdoor unit, such as balconies, roofs, 

        floors, also can be installed in the room.
2.2  Water tank must be standing install, the installation place is a solid foundation, must be bear  the 
        weight of  the tank when full of water.
2.3  Around the water tank , as well as water pipes and hot water pipes should install a valve.
2.4  Do not install the water tank, where exist pollute and corrosive gases.

3.    The unit  and water tank installation

3

.1  Unit install base is concrete structures, also can be made of steel angle brackets, plus vibration rubber 

       pad placed on the ground or roof, to ensure the unit horizontally.
3.2  Installed base design should in accordance with units and water tanks installed size And operational 
       quality.
3.3  Directly use expansion bolts to fix unit and water tank to the concrete base.
3.4  Around the unit and tank should be drain or outlet.

1.   

Unit installation position

1.   Unit installation position

III.  Installation

1.1  

Please keep enough space around the  unit for repair. Correct and wrong  means as below:

Wrong

 Correct

Содержание MWCRW045Z

Страница 1: ...Macon Cooling and Heating Energy efficient Equipment Co Ltd Macon Cooling and Heating Energy efficient Equipment Co Ltd MULTI FUNCTION WATER TO WATER MACON MACON...

Страница 2: ...nstallation diagram 6 Installation of the temp detector 7 Electrical wiring 8 Electrical Wire Selection 9 Trial run 10 IV Function diagram of the remote controller Controller parameter Table V Mainten...

Страница 3: ...the neutral and or tap water pipe 2 4 The wire must be joined in compliance with the requirements of the wiring chart Do not alternate and or repair the unit personally 2 5 The water temperature will...

Страница 4: ...mitted A Horizontal fan direction B Upward fan direction Design alternative serial number The figure represents the horse power of unit eg 010 means 1 horse power 4 Product work principle The dotted l...

Страница 5: ...ressor Compressor Qty Noise Water Flow Volume Water Pressure Drop Water Connection Water Flow Volume Water Pressure Drop Water Connection Water Flow Volume Water Pressure Drop Water Connection Refrige...

Страница 6: ...2 10 12 40 2 10 12 40 2 1500 980 1080 1600 1060 1220 400 450 450 500 250Z S 70 4 240200 91 5 312300 1875 23 20 22 04 40 7 38 7 380 3 50 3 0 0 05 Scroll 4 56 10 12 40 2 10 12 40 2 10 12 40 2 1500 980...

Страница 7: ...Dimensions Dimensions MACON MACON MACON Multi Function Water To Water Heat Pump 3 Product appearance and installation dimension 1 Installation dimensions of integrated type unit 5 5...

Страница 8: ...ing install the installation place is a solid foundation must be bear the weight of the tank when full of water 2 3 Around the water tank as well as water pipes and hot water pipes should install a va...

Страница 9: ...filter to reduce the water system resistance loss 5 7 The unit air conditioning side and the hot water side which connect to running water must be installed a one way valve filter and pressure relief...

Страница 10: ...ensure that the unit s maximum starting current requirements 7 3 The unit power supply circuit must have a grounding wire which should connect with a reliable external ground wire and the external gr...

Страница 11: ...line of board in the electrical box 7 8 Unit control panel Code MK3051 Fuse specifications 5A 250V 8 Electrical Wire Selection 8 1 Voltage drop occur may due to the large current draw during compress...

Страница 12: ...Z S 200Z S 200Z S 300Z S 450Z S 220V 1PH 50Hz 2 2 5mm 2 mm 380V 3PH 50Hz 2 2 5mm 2 mm 2 2 5mm 2 mm 2 2 5mm 2 mm 2 2 5mm 2 mm 2 2 5mm 2 mm 2 2 5mm 2 mm 2 2 5mm 2 mm 2 2 5mm 2 mm 2 2 5mm 2 mm 2 4 0mm 2...

Страница 13: ...art the hot water side air conditioning side solar side circulating pump opened the exhaust valve again to drain the pipe air observe and listen water pump operation the circulating water flow whether...

Страница 14: ...d be equipped with automatic exhausted valve which is in stalled at the highest of the water system refer to the pipe connection explanation The factory 12 12 Multi Function Water To Water Heat Pump M...

Страница 15: ...cle pump Hot water cycle pump Solar collector temperature sense Air condition electric heater temperature protect switch Mk3052 Controller Mk3051 Room 1 Turn ON OFF Room 2 Room N 220V 50HZ Electricity...

Страница 16: ...r Prg Prg Ese Ese UNIT ON OFF SET BACK UP DOWN ENTER Press this button to control the unit s ON or OFF Press this button to enter the main menu interface Press this button to return to the previous sc...

Страница 17: ...ating inlet temp Hot water mode Hot water temp H W Aux Heating A C Aux Heating Cooling 12 40 on 55 on off off Prg Prg Ese Ese Main menu Maintenance Clock Under the main interface press enter into para...

Страница 18: ...inlet G S water outlet 40 45 55 65 13 13 50 13 MACON Prg Prg Ese Ese H W aus Heater Comp Oil Heater 3 way valve on off on off on off Prg Prg Ese Ese A C flow sw G S flow sw H W flow sw Sys1 HP sw Sys...

Страница 19: ...e Ese 6 1 A C Pump 6 2 Hot Water Pump 6 3 G S Water Pump 6 4 Solar Pump on off on off on off on off Select Heat pump Select Defrost Select Aux heating Select Pump testing Select Systems Prg Prg Ese Es...

Страница 20: ...e value press the key again confirm and exit press the to return the layer menu Ese Ese 3 When you select Timer on press the key regular on or off setting flash press key to modify the boot time wheth...

Страница 21: ...lve on off Fan motor on off air condition cycle water pump on off Hot water cycle pump on off Solar cycle pump on off measured value measured value Actual state Actual state Actual state Actual state...

Страница 22: ...pump on off air condition cycle water pump on off Hot water cycle pump on off Solar cycle pump on off measured value measured value Actual state Actual state Actual state Actual state Actual state Act...

Страница 23: ...m 2 double system A to W W to W 50 50 30 125 1 50 2 99 10 30 Normal Special On off On off A C H W 1 W to W 15 48 10 Special Off Factory setting Adjustable Factory setting Factory setting Adjustable Ad...

Страница 24: ...is open or short circuit The sensor is open or short circuit The sensor is open or short circuit The sensor is open or short circuit The sensor is open or short circuit The sensor is open or short cir...

Отзывы: