1.0 Heat pump
2.0 Defrost
Parameter
1.1 cooling inlet 12
1.2 cooling
T1 4
1.3 heating inlet temp. 40
1.4 heating
T2 5
1.5 hot water temp. 55
1.6 hot water
T3 5
cooling inlet tempture setting
cooling start temperature
difference setting
heating inlet tempture setting
heating start temperature
difference setting
Tank hot water tempture setting
Tank hot water heating start
temperature difference setting
8
18
1
20
18
60
1
60
30
60
1
20
2.1 Def. Cycle 40M
2.2 Def. inlet temp. -3
2.3 Def. outlet temp. 13
2.4 Def. Max. time 12M
defrosting cycle setting
Start defrosting coil temperature setting
Exit defrost temperature setting
Defrost time setting
1min
90min
-20
-10
1
30
1min
12min
45min
-3
13
12min
Adjustable
Adjustable
Adjustable
Adjustable
Adjustable
Adjustable
Adjustable
Adjustable
Adjustable
Adjustable
12
5
40
5
55
5
5
5
3.1 A.C. Aux.
T 5
3.2 H.W. aux.
T 5
air condition auxiliary heating start
temperature difference setting
Hot water auxiliary heating start
temperature difference setting
1
20
1
20
Adjustable
Adjustable
3.0 Aux-heating
Unit status
A.C. Inlet temp. 45
A.C. Outlet temp. 45
Hot water temp. 40
Rec. inlet temp. 65
air condition water inlet tempture
air condition water outlet tempture
tank hot water tempture
Heat recovery water inlet temperature
measured value
measured value
measured value
measured value
Solar temp. 50
Ambient temp. 13
Compressor 1 on/off
Compressor 2 on/off
4way-valve on/off
G.S.water pump
on/off
A.C. water pump on/off
Hot water pump on/off
Solar pump on/off
Solar collector water temperature
Ambient temperature
1 system compressor on/off
2 system compressor on/off
4way-valve on/off
ground source water pump on/off
air condition cycle water pump on/off
Hot water cycle pump on/off
Solar cycle pump on/off
measured value
measured value
Actual state
Actual state
Actual state
Actual state
Actual state
Actual state
Actual state
measured value
measured value
A.C.aus. heater on/off
H.W. aus. Heater on/off
Comp. Oil Heater on/off
air condition auxiliary electric
heater on / off
hot water tempture auxiliary electric
heater on / off
compressor oil tempture auxiliary
electric heater on / off
3 way-valve on/off
Water 3 way-valve on / off
air condition side water flow switch
close or open
ground source side water flow switch
close or open
hot water side water flow switch close
or open
1 system high pressure switch close
or open
1 system low pressure switch close
or open
2 system high pressure switch close
or open
2 system low pressure switch close
or open
Air-conditioning auxiliary heater,
thermal protection switch close or open
A.C. flow sw close/open
G.S. flow sw close/open
H.W. flow sw close/open
Sys1 HP sw close/open
Sys1 LP sw close/open
Sys2 HP sw close/open
Sys2 LP sw close/open
A.C. aux.TH sw close/open
H.W. Aus.TH sw close/open
Emergency Sw close/open
Phase sw close/open
Actual state
Actual state
Actual state
Actual state
Actual state
Actual state
Actual state
Actual state
Actual state
Actual state
Actual state
hot water auxiliary heater, thermal
protection switch close or open
Emergency Switch
(close:working ;open:stop working)
close:Normal; open:Phase, phase
sequence wrong.
G.S.water inlet 13
G.S.water outlet 13
1 system evaporator coil temperature
(ground source water inlet temperature)
2 system evaporator coil temperature
(ground source water outlet temperature)
Water to water
Display code1
Display code2
Setting data explanation or
working state
Parameter
setting range
Default
Remarks
Multi-Function Water To Water Heat Pump
MACON