MACON
Prg
Prg
Ese
Ese
Main menu
Parameter
Maintenance
Clock
Prg
Prg
Ese
Ese
1: E01 2010-01-14 09:00
2: P01 2010-01-14 09:10
3: E08 2010-01-14 09:30
4: E05 2010-01-14 09:40
5: P06 2010-01-14 09:50
6: P08 2010-01-14 10:00
7: P12 2010-01-14 10:10
8: E07 2010-01-14 10:20
Prg
Prg
Ese
Ese
Main menu
Parameter
Maintenance
Clock
Prg
Prg
Ese
Ese
Date
Clock
Timer on
Timer off
2010-04-15
18:30
X
X
Prg
Prg
Ese
Ese
E08
ambient temp.sensor
failure
Alarm
1.6.The maintenance time inquires ;
In the interface ,press
to enter parameter setting interface,choose "Maintenance'' and
press
to enter Maintenance time inquires, press
to turn a choice, and press
key
returns the last menu.
Prg
Prg
Ese
Ese
1.7.Date/ time/ timing on and off settings:
In the main interface, press
key to enter the parameter setting interface, select Clock, press
key to enter the time setting / timing on or off interface, press the
key to turn options:
Prg
Prg
1, when you select "Date", press
key, the date of the year setting flash, press the
key
to modify Year, then press
key again, the month setting flash, press the
key to modify the
month, click the
key again, Day flash, press the
key to modify the day, then press
key to confirm and exit, press the
button to return the layer menu.
Ese
Ese
2. When you select "Clock", press the
key, the time hourly position flash, press the
key
to modify hour value, then press
key, minutes flash, press the
key to modify the minute value,
press the
key again confirm and exit, press the
to return the layer menu.
Ese
Ese
3. When you select "Timer on", press the
key, regular on or off setting flash, press
key
to modify the boot time whether on / off, appear "
" symbol when choose on, and show regular boot time
settings, click the
key, regular on or off hour value setting flash, press the
key to modify the
value, then press
key, regular on or off minute value setting flash, press
key to modify the
value, press
key to confirm and exit, press the
"Ese" to return the layer menu.
Ese
Ese
4. When you select "Timer off", press the
key, time off setting flash, press the
key to
choose the sleep timer whether on / off, it will appear "
" symbol when choose, and shows the value of time
off setting, press
key, timer off hour value setting flash, press the
key to modify the value,
then press
key, time off minute value setting flash , press
key to modify the value, press
key to confirm and exit, press the
to return the layer menu.
Ese
Ese
1.8.Fault code display:
When a fault, unit controller display automatically corresponding fault code and the fault reasons.
When fault resolution, fault display automatically eliminate or after re-power to eliminate
18
18
1.9.
Lock button/
Fahrenheit
and
Celsius
change:
Display Lock
Under the power on or standby status:Press
for 10s, all buttons on the display are
locked, but it can be unlocked after pressing
for 10s again.Shows
Multi-Function Water To Water Heat Pump
Fahrenheit
and
Celsius
change
Under the Celsius status, press
for 10 s can change to
Fa h ren
heit
,it wi ll ch ang e to Cels iu s again w
hen p ress
f o r 1 0s .
Ese
Ese
Ese
Ese