WINDROWER OPERATION
Form 169552 / 169554 / 169555
52
Revision A
6.3.3 PRE-SEASON CHECK
a. Perform the following safety checks at the
beginning of each operating season:
CAUTION
•
Review the Operator's Manual to refresh
your memory on safety and operating
recommendations.
•
Review all safety signs and other decals
on the windrower and note hazard areas.
•
Be sure all shields and guards are
properly installed and secured. Never
alter or remove safety equipment.
•
Be sure you understand and have
practiced safe use of all controls. Know
the capacity and operating
characteristics of the machine.
•
Store a properly stocked first aid kit and
charged fire extinguisher on the
windrower.
b. Perform the following checks:
1. Drain off excess hydraulic oil added for
storage. Refer to Section 7.11.2
Changing
Hydraulic Oil
.
2. Remove plastic bags and/or tape from all
sealed openings (air cleaner intake, exhaust
pipe, fuel tank).
3. Charge battery and install. Be sure terminals
are clean, and cables are connected
securely.
4. Adjust tension on A/C compressor belt. See
Section 7.8.10.1 Tension.
5. Check the entire air conditioning system for
leakage at the beginning of each season.
6. Cycle A/C switch to distribute A/C refrigerant
oil as follows:
IMPORTANT
Perform the following steps whenever the
machine is first started after storage for
more than one week:
i. Turn blower switch to “first” position, turn
temperature control switch to maximum
heating, and A/C control to OFF.
ii. Start engine, and operate at low idle until
engine is warm.
iii. Click A/C switch from OFF to ON for one
second, then back to OFF for 5 to 10
seconds. Repeat this step ten times.
c. Perform annual maintenance. See Section 7.13
MAINTENANCE SCHEDULE.
6.3.4 DAILY CHECK
a. Check the machine for leaks or any parts that
are missing, broken, or not working correctly.
NOTE:
Use proper procedure when searching for
pressurized fluid leaks. Refer to Section
7.11.7 Hoses and Lines.
b. Clean the windows and mirrors to be sure of
good visibility in all directions. Stand on the
platform to access the rear window. Hold onto
the hand-holds on the cab front corners, and
stand on the header anti-slip strips to wash the
front window.
c. Clean all lights and reflective surfaces to
maintain visibility to others.
d. Perform Daily maintenance. Refer to Section
7.13 MAINTENANCE SCHEDULE.
TEMPERATURE CONTROL
Controls Cab Temperature
INCREASE - Clockwise
DECREASE - Counter Clockwise
BLOWER SWITCH
Controls Blower Speed
OFF / LOW / MEDIUM / HIGH
AIR CONDITIONING SWITCH
Controls A/C System
OFF - A/C Does Not Operate
ON - A/C Operates With Blower
Switch ON