5.2 Installation and Strapping of the UPS
CAUTION: RISK OF PERSONAL INJURY AND EQUIPMENT DAMAGE.
1.
The strapping of the UPS to the Mac Victor 2.0 shelf is strongly recommended before the UPS has been
started up and is fully operational. Strapping requirements may vary for different localities so consult
with the local Authority Having Jurisdiction (AHJ) for specific strapping requirements and / or materials.
2.
The Mac Victor 2.0 has an integrated UPS shelf with total of 4 strapping slots (2 front and 2 back) to
accommodate the installation of 2 separate straps.
3.
Mount the UPS on top of the Mac Victor 2.0 Shelf with the front of the UPS facing to the left (outlets
and power cord facing the right)
4.
The UPS should be located on the shelf in a position that insures adequate rear ventilation of the UPS
(surface facing the back wall) according to the UPS Manual. Do not block the UPS ventilation holes.
5.
The Mac Victor 2.0 comes with 2 – 8’ straps (½” wide polypropylene - 600 lb rated), 2 wire buckles, and 4
edge protectors for use on top of the UPS. Install the 2 sets of strapping, edge protectors, and wire
buckles as shown in Figure 5.3 to secure the UPS.
Mac Victor 2.0
(Right hand side view)
UPS
(Right hand side view)
Figure 5.3
Edge Protectors (4)
Wire Buckle (2)
Straps (2)
CAUTION: Important UPS limitations
UPS External Battery cabinets are not
permitted on the Mac Victor 2.0 Shelf
and must be located separately
Maximum UPS width = 8.6 inches
Maximum UPS weight = 95 lbs.
Uninterruptible Power Supply (UPS)
8.6” maximum