Spa Installation
Danger: Electrical shock risk. Install at least 5 ft.
(1,5 m) from all metal surfaces.
The electrical supply for this product must
include a suitably rated switch or circuit breaker to
open all ungrounded supply conductors to comply with
Section 422-20 of the National Electrical Code, ANSI/
NFPA70-1987. The disconnecting means must be
readily accessible but installed at least 5 feet (1.5
meters) from the spa water. All electrical connections
should comply with article 680-D of the NEC.
Site and Positioning
Locate the spa on solid, level foundation or
flooring, keeping in mind the weight of the filled spa
(in excess of 4,000 lbs. on some models). If you have
any doubts about the load bearing ability of your
chosen site, contact an architect or a building
contractor. The entire perimeter of the spa cabinet and
the spa bottom must be evenly supported.
If your spa is installed outdoors, we recommend
that you provide a concrete pad for the spa to rest on
(8ft. x 8ft. x 4” level pad). Failure to provide a level
surface could structurally damage your spa and void
the warranty.
The spa must be installed to allow access for
service and maintenance on all four sides; therefore,
below grade level installation is not recommended.
Outdoor Installation
The following considerations apply when installing
your spa outdoors:
1. Local codes pertaining to fencing.
2. Local electrical and plumbing codes.
3. View from your house.
4.
Wind
direction.
5. Exposure to sunlight.
6. Location relationship to trees (twigs, leaves
and
shade).
7. Dressing and bathroom location.
8. Storage area for maintenance equipment
and
chemicals.
9. Location to facilitate adult supervision.
10. Landscaping and nighttime lighting.
11.
Accessibility
to
equipment.
12. Power supply location and foot traffic.
Indoor Installation
The following considerations apply when installing
your spa indoors:
1. Indoor spas promote high humidity. Using either
ventilation fans or commercial grade de-humidifiers
will help to reduce the humidity. Consult your dealer
for details.
2. Floor drains must be provided near the spa to drain
off water that may cause falls and /or water damage.
3. Floor area should be flat with a non-skid finish.
Carpeting is not recommended.
4. Walls, ceilings, woodwork should be made of
materials capable of withstanding high humidity
(redwood, cedar).
5. Be sure floor load bearing capacities are adequate to
support the concentrated spa weight.
6. Spas should be double checked for leaks before
installing to avoid possible water damage. Dealer
installation may include this service.
7. Indoor sunrooms are capable of maintaining high
ambient temperatures which may effect the spa water
temperature. It is
NOT
recommended that you operate
your filter cycles for longer than 6 hours per day under
these conditions.
Содержание 2007 Elite spas
Страница 1: ...1 2007 OWNER S MANUAL...
Страница 20: ...20...
Страница 26: ...26...
Страница 43: ...43 165 Series System Wiring Diagram...
Страница 44: ...44 167 Series System Wiring Diagram...
Страница 45: ...45 460 Series System Wiring Diagram...
Страница 46: ...46 760 Series System Wiring Diagram RED 1 2 3 4 WHT GRN RED 1 2 3 4 WHT GRN...