background image

SWIFT CURRENT SPA

Swift Current

Swift Current

 

Foam Wall Spa

Foam Wall Spa

w w w . c a n a d i a n S p a c o m p a n y . c o m

Instruction Manual

220-240V 50Hz 13A

Read this Manual before operation

c a n a d i a n s p a c o m p a n y . c o m

Summary of Contents for KP-10008

Page 1: ...Swift Current Swift Current Foam Wall Spa Foam Wall Spa w w w c a n a d i a n S p a c o m p a n y c o m Instruction Manual 220 240V 50Hz 13A Read this Manual before operation c a n a d i a n s p a c...

Page 2: ...5 feet 1 5 m from all metal surfaces DANGER Risk of Electric Shock Do not permit any electrical appliances such as a light telephone radio or television within 5 feet 1 5 m of a spa DANGER Risk of Ac...

Page 3: ...est Certificate Pump only Heating Efficiency Ambient temperature is 68 F 20 C Jets KP 10008 CA17690GB Swift Current 5 Persons 160 x 73cm 63 x 29 184cm x 73cm 73 x 29 1000L 220 240V 50Hz 2040W L1 400W...

Page 4: ...ollowing key components are present 4 Top Liner x 1 Filter Cartridges x 2 Foam Caps x 8 Portable Control Unit PCU x1 Hard Top Cover Lid x 1 Inflation Hose x 1 Bottom Liner x 1 Inlet Outlet Caps x 2 Dr...

Page 5: ...trawberry Champagne Classic Universal Step KF 10061 Simple to assemble these spa steps allow for quick and easy entry into a spa while providing a non slip surface for safety No tools required to asse...

Page 6: ...IS IMPORTANT YOUR SPA IS LEVEL After filling your spa check the water level against the wavy red lines marked on 3 sides of the spa If the water level matches on the 3 sides your spa will be level 3 S...

Page 7: ...Liner Ensure you put the cut out of the drain fig a inside to the left of the three holes fig a OUTSIDE INSIDE 4 Connecting the PCU to the Spa Insert the three connectors into the three holes of the l...

Page 8: ...light turns green 3 Press the TEST button the indicator light turns off 4 Press the RESET button the indicator light turns green the pump is ready to use 5 Install the Filter Cartridge Firstly check t...

Page 9: ...temperature The value will increase or decrease by 1 F 1 C for each press Temperature Adjustment Ranges 86 F 103 F 30 C 39 C NOTE There may be a 3 4 degree variance between the temperature shown on th...

Page 10: ...hich will be indicated with a flashing red light NOTE Heater will not resume until spa water drops 2 degrees below set temperature for maximum efficiency You can also manually restart the heater by pr...

Page 11: ...A reminder CHG FIL will appear to change the filter after 25 days Hold down HEAT for 5 seconds to clear the message Change water once a month or depending on usage and use appropriate spa chemicals P...

Page 12: ...store in a warm dry place Storage Use a towel to wipe off the spa and dry for 24 hours Unscrew the Air Valve on the lid Unzip the liners and gently fold them for storage along with the foam panels It...

Page 13: ...s over 122 F 50 C 1 Unplug the RCD cable from the outlet 2 See Part 8 Spa Operation Check List for possible solutions 3 Power on spa again to see if error is resolved if not please contact for service...

Page 14: ...Not Working Dirty filter cartridge Inlet outlet port blocked Air lock Something is wrong with the control panel Clean replace the filter cartridge every 3 4 weeks check white filter grid under filter...

Page 15: ...ance Germany Ireland Italy Netherlands Spain or the United Kingdom and the same model as this spa is sold at the same voltage rating in the relevant country What is not covered Canadian Spa Company do...

Page 16: ...5GL UK T 44 1293 824094 canadianspacompany co uk North America Office Canadian Spa Company 1283 Cornwall Rd Oakville ON L6J 7T5 Canada T 1 877 909 7727 canadianspacompany ca German Office Canadian Sp...

Reviews: