Temperature
The maximum set temperature is 104°F
(40°C) and the minimum set temperature is 80°F
(27°C). The current water temperature or, if the pump
has not been running, two dashes, will show on the
display. If dashes are displayed, you must first start
the pump by pressing the
JETS 1
pad. Wait until the
water temperature is displayed (approximately 2
minutes).
The set temperature of your spa may easily be
increased or decreased at any time using the
WARM
or
COOL
pads. When either of these pads is touched,
the set temperature will be displayed in the LCD
window. Each successive touch will change the set
temperature 1°F in the chosen direction. After 3
seconds the LCD will automatically display the water
temperature or dash lines.
If the spa is set in
Standard
mode or in a
filtration cycle, adjusting the set temperature may
result in activating the heater. When the heater is
operating, the heat icon will be displayed in the LCD.
Note:
240-Volt spas that are wired with the 30 Amp
option will not heat when Pump 1 is on in high speed,
or when Pump 2 is in operation.
JETS 1
Touch
the
JETS 1
pad to activate the primary
filtration pump. The sequence of the jet action is:
1 touch = Low jets
2 touches = High jets
3 touches = Off
JETS 2
Touch
the
JETS 2
pad to activate the therapy
pump. The sequence of jet action is:
1 touch = Low jets
2 touches = High jets
3 touches = Off
The low speed operation of Pump 1 is timed to
automatically turn off after two hours of operation.
The high speed operation of Pump 1, and the low and
high speed operation of Pump 2, is timed to
automatically turn off after 15 minutes of operation.
Note:
Pump 1 will automatically operate in low speed
whenever the spa calls for a filtration cycle or heat.
When this automatic activation occurs, the low speed
of Pump 1 cannot be turned off; however, all other
control functions can be activated.
Temperature Lock
Once you have set the desired water
temperature, you may lock-in the new setting to
prevent unauthorized temperature adjustments to your
spa. To lock the set temperature:
Touch
WARM
or
COOL
, then touch
TIME
,
JETS 1
,
and
WARM
within 3 seconds. The “
TL
” indicator
will light when the set temperature is locked.
Temperature
Unlock
To unlock the temperature, touch either
WARM
or
COOL
, then touch
TIME
,
JETS 1
, and
COOL
within 3 seconds. The “
TL
” indicator light will go out
when the set temperature lock is cleared.
Panel Lock
To help prevent unauthorized use of your spa, the
control system has a unique panel locking system.
To lock the panel, touch
TIME
,
JETS 1
, then
WARM
within 3 seconds. When locked, the “
PL
”
indicator light will be on. Except for the time button,
everything will be frozen.
When the control panel lock is
engaged, all automatic spa functions will operate
normally but cannot be altered.
Panel Unlock
To unlock the panel, touch the
TIME
,
JETS 1
, and
COOL
within 3 seconds. The “
PL
” indicator light will
go out when the panel lock is cleared.
Light
Touch the
LIGHT
pad to turn the digital lighting
system on and off. The light will automatically turn
off after 60 minutes of operation.
Содержание 2007 Elite spas
Страница 1: ...1 2007 OWNER S MANUAL...
Страница 20: ...20...
Страница 26: ...26...
Страница 43: ...43 165 Series System Wiring Diagram...
Страница 44: ...44 167 Series System Wiring Diagram...
Страница 45: ...45 460 Series System Wiring Diagram...
Страница 46: ...46 760 Series System Wiring Diagram RED 1 2 3 4 WHT GRN RED 1 2 3 4 WHT GRN...