18
Changing Modes
To change the operating mode, press the “
Temp
”
button then the “
Light
” button. Continue this
sequence until the desired mode is displayed in the
LCD window.
Filtration Cycles
The control system on your spa has been
designed to function properly and safely at 100oF after
connecting the electrical wires and installing the
proper grounds. To take full advantage of the unique
capabilities of your new spa, you should first establish
your filtration cycles.
Preset Filter Cycles
The 160 Series control systems are designed
with two filter cycles. The first filter cycle turns on 6
minutes after power is supplied to the spa. The second
filter cycle turns on 12 hours later. The duration of
each filter cycle is per-set at the factory for two hours,
or a total of 4 hours per day.
Changing Filter Cycle Start Time
The start time of the first filter cycle begins 6
minutes after the set time is established. The set time
is based on the time of day that the spa is powered up.
The set time can only be changed by disconnecting
power from the spa and re-connecting it at the desired
start time. For example, if you want the filter cycle to
begin at 9:00PM, unplug the spa and re-connect it at
8:54PM. The first filter cycle will begin at 9:00PM,
and the second filter cycle will begin 12 hours later at
9:00AM. Each cycle will run for the prescribed
number of hours.
Changing Filter Cycle Duration
The duration of a filter cycle is programmable
for 2, 4, 6, or 8 hours, or for continuous filtration.
Each duration runs once every 12 hours, or twice per
day. For example, a 2 hour cycle will complete once
every 12 hours for a total of 4 hours of filtration per
day. Continuous filtration will run for 24 hours per
day. The amount of time needed to filter your spa will
depend on usage and ambient conditions. You will
need to program your filter cycles based upon your
personal use.
To change the duration of the filter cycles,
touch the “
Temp
” button then the “
Jets 1
” button.
Press the “
Temp
” button to toggle through the
different duration options as shown below. Press the
“
Jets 1
” button to exit the programming sequence.
F2
2 Hours for each cycle, 4 hours per day
F4
4 hours for each cycle, 8 hours per day
F6
6 hours for each cycle, 12 hours per day
F8
8 hours for each cycle, 16 hours per day
FC
Continuous filtration, 24 hours per day
If a change is made to the duration while the
spa is in a filtration cycle, it will take effect
immediately. If a change is made outside a filtration
cycle, it will take effect at the start of the next
scheduled cycle.
Note:
If power is interrupted to the spa (disconnected,
power outage, etc), the control will revert to the
default factory settings. Any adjustments to set
temperature filter cycle start time, or filter cycle
duration will need to be reprogrammed.
Note: If your spa is equipped with a second pump, it
will be activated for 15 seconds at the start of each
filtration cycle to clear the water in the pipes and
ensure complete filtration.
Clean Up Cycle
After periods of heavy use, you can manually
start a clean-up cycle by turning Pump 1 on in low
speed. The pump will operate for 4 hours and then
automatically turn off. The heater will also operate
during this period if the controls are set in the Standard
mode.
Содержание 2007 Elite spas
Страница 1: ...1 2007 OWNER S MANUAL...
Страница 20: ...20...
Страница 26: ...26...
Страница 43: ...43 165 Series System Wiring Diagram...
Страница 44: ...44 167 Series System Wiring Diagram...
Страница 45: ...45 460 Series System Wiring Diagram...
Страница 46: ...46 760 Series System Wiring Diagram RED 1 2 3 4 WHT GRN RED 1 2 3 4 WHT GRN...