7.4
Link In- and Output
Linking of dimmers is possible by using the LINK interface.
The playback functions of the Memory menu are transferred: "OFF, Chaser, MEMORY 1...12".
Other functions are not transferred.
Attention!
For this function a 5 wire DIN-cable must be used; MIDI cables often have only 3 wires!
This cable is connected with the MASTER dimmer (LINK-OUT) and the SLAVE dimmer (LINK-IN). The
rest of the SLAVE dimmers are connected from LINK THRU to LINK IN.
Linking the dimmers is advisable when the light must be controlled only by dimmers without any other
input control (e.g. if the light control desk fails). Other examples of use are test functions, focusing
only with one operator and "booth lighting" at fairs.
7.5 Power Supply see chapter 5.1
7.6 Load Output
Pinout for the Wieland connectors (dimmer 12x2,3 kW, 12x3,7 kW)
top plug:
Pin 1...6
Phase 1...6 bottom plug:
Pin 1...6
Phase 7...12
Pin 9...14
Neutral 1...6
Pin 9...14
Neutral 7...12
all Neutrals are connected inside the unit.
Pinout for the Wieland connectors (dimmer 6x5,7 kW)
top plug:
Pin 1,3,5
Phase 1...3 bottom plug:
Pin 1,3,5
Phase 4....6
Pin 2,4,6
Neutral 1...3
Pin 2,4,6
Neutral 4....6
all Neutrals are connected inside the unit.
Pinout for the Socapex connector:
top plug:
Pin 1
Phase 1
bottom plug:
Pin1
Phase 7
Pin 2
Neutral
Pin 2
Neutral
Pin 3
Phase 2
Pin 3
Phase 8
Pin 4
Neutral
Pin 4
Neutral
Pin 5
Phase 3
Pin 5
Phase 9
Pin 6
Neutral
Pin 6
Neutral
Pin 7
Phase 4
Pin 7
Phase 10
Pin 8
Neutral
Pin 8
Neutral
Pin 9
Phase 5
Pin 9
Phase 11
Pin 10
Neutral
Pin 10
Neutral
Pin 11
Phase 6
Pin 11
Phase 12
Pin 12
Neutral
Pin 12
Neutral
Earth is connected to pin 13...19 on both plugs.
Channel order of the Hot Patch Field:
View from the backside: Starting at top left, 1st and 2nd row parallel: 2 times channel one, 2x channel
2, 2x channel 3 and last in the row 2x channel 4 one on top of the other.
The 3rd and 4th row starts accordingly with 2x channel 5 etc. etc..
Warning: When Socapex and Wieland St17 connectors are used at the load output, an
additional earth cable between dimmer and load cable and/or load distribution must be used.
Reason: The Socapex connector has no earth contact which is conducting at first.!
At any rate the connectors should only be moved when the dimmer is switched off!