M2 Antenna Systems RC2800PRKX2SU Скачать руководство пользователя страница 4

 

 

RUN MODES:

 

Modes 0, 1 and 2 are all run modes capable of activating the positioner in both the CCW / DWN and CW / UP

 

direction. 

 

 

 

MODE 0

 = 

MANUAL OPERATION MODE:  

 

Pushing the CCW button activates the positioner in the Counter Clockwise direction, and the Heading count will 

go down. Pushing the CW button activates the positioner in the Clockwise direction, and the Heading count will 

go up. Pressing the UP button activates a specific positioner in the Upward direction and the Heading count will 

go up. Pressing the DWN button activates the positioner in the Downward direction and the Heading count will 

go down. The positioner runs while CCW / DWN or CW / UP button is depressed, ramping up from minimum 

programmed  speed  to  the  maximum  (9)  and  then  again  ramping  down  to  speed  (1). 

When  reversing             

direction, there is a 2

-

3 second delay before the positioner is activated. 

 This delay reduces stress on your 

antenna and positioner. 

*This Mode can also be initiated from the M2 Setup Utility Software. *See  the M2 

Setup Utility usage page for more details

 

 

 

NOTE:

 

Rotation  direction, 

i.e.,

  CCW  /  DWN  or  CW  /  UP  is  defined  as  if  you  are  looking  down  on  the  positioner  /        

antenna from above.

 

 

 

MODE 1

 = 

SERVICE / MAINTENANCE MODE

:

 

When the Service / Maintenance Mode is initiated, the controller will not respond to any computer commands. 

This allows service or maintenance issues to be addressed without the danger of the service technician being 

injured. While in Mode 1, the controller can be commanded with both the CCW/DWN or CW/UP buttons to put 

the positioner or positioners

’ 

into a stowed position for service or repair. When  service is completed, the control 

unit must be placed back into MODE 0 (from controller panel)  for computer commands. 

 

 

  

 

 

MODE 2

 = 

PRESET MODE:

 

Preset mode is another Service / Maintenance oriented mode. When the Preset Mode is initiated, the controller 

will not respond to any computer commands. Again this allows service or maintenance issues to be addressed 

without injury.  The user can program up to (10) Presets per Axis for use in stowing or rotating the positioner or           

positioners

’ 

to a known heading for service or repair. Preset headings are programmed into the controller with 

the use of the supplied M2 Setup Utility Software. Once the presets are programmed, the user selects with the 

CCW / DWN and CW / UP buttons. Motion is initiated to the displayed preset heading after selecting the preset 

and NOT pressing any button for 3 seconds. When service is completed, the control unit must be placed back 

into MODE 0 (from controller panel)  for computer commands. 

 

 

              USER DEFINED PRESETS

 

 

ELEVATION 

PRESET

” 

HEADINGS

 

20

 

 

21

 

 

22

 

 

23

 

 

24

 

 

25

 

 

26

 

 

27

 

 

28

 

 

29

 

 

AZIMUTH 

PRESET

” 

HEADINGS

 

20

 

 

21

 

 

22

 

 

23

 

 

24

 

 

25

 

 

26

 

 

27

 

 

28

 

 

29

 

 

POLARITY 

PRESET

” 

HEADINGS

 

20

 

 

21

 

 

22

 

 

23

 

 

24

 

 

25

 

 

26

 

 

27

 

 

28

 

 

29

 

 

BASIC OPERATIONS / RUN MODE DESCRIPTIONS

 

Содержание RC2800PRKX2SU

Страница 1: ...2 FEATURES The M2 RC2800PRKX2SUMC is our Mid Grade rack mount controller The RC2800PRKX2SUMC was developed for Commercial Grade AZ EL Pedestal Models AE1000 AE1000CB and AE1000CBW Also available for a...

Страница 2: ...and PROGRAM MODE details following this section SPEED BUTTONS The SPEED buttons control the positioner s rate of speed in relative increments 1 is the slowest speed 9 is the fastest The top button in...

Страница 3: ...itioner unit The cable supplies pow er and data from the positioner Your ground connection is terminal 12 DISCONNECT THE AC POWER CORD WHEN CONNECTING CABLE LEADS RC2800PRKX2SUMC UNITS WITH HEATER If...

Страница 4: ...er commands This allows service or maintenance issues to be addressed without the danger of the service technician being injured While in Mode 1 the controller can be commanded with both the CCW DWN o...

Страница 5: ...he positioner to either the CCW DWN or CW UP limit switch location Note During Auto Cal the positioner WILL bypass the electronic limit to find either the CCW DWN or CW UP limit switch Rotator Locatio...

Страница 6: ...e controller for use by the Auto Cal Function Display Brightness Changes the brightness level of the LED Display Firmware Version Displays the current firmware from the controller when connected Read...

Страница 7: ...sed when less than 360 of travel is necessary with a southern exposure and avoids limits where most of the operations are being preformed Note the position of the Physical limit switches they are on t...

Страница 8: ...amount 10 SU Designation Azimuth N Center OVERVIEW This azimuth configuration may be used when 240 of travel is necessary with primarily a northern exposure and avoids limits where most of the operati...

Страница 9: ...10 UP ELECTRICAL LIMIT 100 ELEVATION AXIS OPTION 1 Characteristics Spectrum of use 0 to 180 plus Over travel amount 10 SU Designation Elevation 180 OVERVIEW This Elevation configuration is used as st...

Страница 10: ...___________________________________________________________________ __ WEST EAST EAST WEST AZIMUTH OPTION 3 AZIMUTH N Center AZIMUTH OPTION 4 AZIMUTH N Center NOTES____________________________________...

Страница 11: ...________________________________________ _________________________________________________________________________________________ _____________________________________________________________________...

Страница 12: ...be 3 You can adjust this by using the Min Speed slide bar in the setup utility The Min Speed is the minimum starting speed However please keep in mind The Min Speed must be set high enough to keep th...

Страница 13: ...ugh the limit switches and through to the positioner When the limit switch is activated it breaks the contact and stops the cur rent from continuing Reversing the positioner in the opposite direction...

Страница 14: ...he rear of the control unit Plug the AC cord into a reliable 115 VAC or 230 VAC source Switching power supplies are used that can operate from 86VAC to 240VAC CUSTOMER NOTE AREA CONNECTIONS AND START...

Страница 15: ...Red Black wires as shown Slide the prepared 2 Conductor Red Black 16AWG wire through the cord grip from the front of the panel Route the Red wire to position A as shown below Then route the Black wire...

Страница 16: ...ioner unit that DOES NOT have cord grips or wires running into it You will see the limit switches A B the limit arm C and limit screw D as pic tured to the right We have not installed the limit screw...

Страница 17: ...ave the choice of setting up either the CCW or CW hard limit as your Auto Cal location If most of your travel happens to be closer to the CW hard limit choose this in the setup utility If not we sugge...

Страница 18: ...rear of the control unit Then verify that the Pulse Divisor is set to the correct value for Elevation 13200 USING YOUR ELEVATION CONFIGURATION WORKSHEET 3 Using your Axis configuration worksheet inse...

Страница 19: ...its Parity Handshake 9600 8 1 None Present not used COMPUTER SOFTWARE CLARIFICATIONS Commands are one letter or two letter one number codes followed by a digit n In many commands the n may be any nume...

Страница 20: ...y Writes EE value yyy into X location The EE locations for X A Limit Switch Tenths of degrees from Initial Cal Heading that trips desired limit switch B Initial Cal Heading Heading to use as Limit Swi...

Страница 21: ...software This is more than 45 degrees CCW DWN from zero 90 when the pulse divider is at it s max of 50 000 We allow 90 degrees with the pulse divider that you are using now E3 Backup No Motion The PO...

Страница 22: ...432 8873 and we will help you trouble shoot the system If the above appears OK then the missing pulses maybe caused by a control cable problem or a damaged Positioner Again turn off the control unit a...

Страница 23: ...see if this wire is shorted to ground If not then the problem may be in the control unit The hexfet could be shorted or the motor drive chip could have failed allowing 10 volts to appear on the gate...

Страница 24: ...ct Some states or provinces do not allow the exclusion or limitation of liability for consequential or incidental damages so the above limitation may not apply In the event repair or replacement are n...

Отзывы: