![M2 Antenna Systems RC2800PRKX2SU Скачать руководство пользователя страница 18](http://html1.mh-extra.com/html/m2-antenna-systems/rc2800prkx2su/rc2800prkx2su_manual_3118852018.webp)
ELEVATION AXIS SETUP AND CALIBRATION:
1. Move the RS232 serial cable to the Elevation port on the back of the controller. Under
“
Rotor Location.
”
Click
“
Connect
”
and once the elevation control board has been verified, the word
“
Connected
”
will appear.
2. Confirm that either the Elevation (90) or Elevation (180) rotator type is selected and that this is the same port
that the serial cable is plugged into on the rear of the control unit. Then verify that the
“
Pulse Divisor
”
is set to the
correct value for Elevation (13200).
USING YOUR ELEVATION CONFIGURATION WORKSHEET:
3. Using your Axis configuration worksheet, insert both the DWN and UP electronic limits into the setup utility. To
finish this process, click the
“
Write Settings
”
button located at the bottom of the utility.
4. At this point, refer to the Azimuth procedures for setup and calibration of your Elevation axis. As both the
Azimuth and Elevation units are very similar regarding setup other than actual degree headings.
ELEVATION AXIS SETUP AND CALIBRATION