R FR 5041 Reference Manual. Rev 1.3
Page 33 of 34
Specifications
Mechanical
Size
1 RU high x 350 mm deep including connectors and front cover.
Standard 19” rack mount.
Weight (empty)
4.5 kg with single power supply and controller
Connections
All connections made on rear of rack
Performance
Available Card Slots
4 x Series 5000 CardModules (single width backplanes)
Power Supplies
1 x Power Supply (primary - included)
Power Indication (alarm)
One multifunction LED on Supply and GPO output
Controller alarm
Multifunction LED (internal)
Connections
(rear connections)
LAN Connector
RJ 45 (10/100 Base T) Full Duplex
Alarm Connector
Terminal strip
Alarm Major and Minor: Relay contact closures
Ref In
BNC connection for rack reference
Analog Bi-level or Tri-level Sync (auto detect)
Primary AC
Standard IEC 60320 C13 AC power connector,
double pole fused (2A) # T2AH250V
External Redundant Power input 12VDC 8A (use R PS 5000 optional power brick)
Electrical Specifications
Power Input
100
– 240VAC, 50Hz – 60Hz.
Power Consumption
100 W max.
Safety
IEC 60950/ EN 60950/VDE 0805
Ambient
Temperature
5°C to 40°C Maintaining specifications
0°C to +50°C Operating
Humidity
Max 90% (non condensing)
Supplied Accessories
Documentation
Reference Manual (CD)
Software
LYNX Desktop Controller Software (CD)