R FR 5041 Reference Manual. Rev 1.3
Page 13 of 34
!
Rack Connections
Rear Termination Panel
The R FR 5041 has an integral termination panel on the rear of the rack for system
connections.
AC Input and Fuses
The AC input is auto sensing
100-250V 50/60Hz
(1.8A nominal) and is located on the
rear of the chassis. Use a standard IEC power cord with a C13 connector for the power
connection. The fuses are located below the AC power input (see below). The system is
double pole / neutral fused so there are two fuses. The fuses are removed by pushing
down on the plastic tab and sliding the fuse carriage out. Insert new fuses and slide the
carriage back in all the way until the tab “clicks” and locks the fuse carriage in place.
Caution
Please remove power before attempting to exchange power fuses. Only replace
the fuse with a correctly rated replacement.
(T2AH250V)
For safety
DO NOT
physically disconnect or isolate the rack from earth for any reason.
Fuse (x2) =
T2AH250V
Push tab down to remove
Fuse carriage removed