12
To Opener
Wire to Opener
13
Sending Unit
Receiving Unit
Terminal Board on the Operator
Wired Infrared Safety Sensor Wiring
Tools Required – Hammer, Small Flat Blade Screwdriver, wire cutter/stripper
Uncoil and route wire from left and right safety
sensors up the garage wall, across the ceiling
and down to front of opener. Tack the wires in
place using wire staples (Not Supplied).
Take care to run wires in a location where they
will not interfere with the operation of the door
or present a hazard to persons in the garage.
Take care to position staples so they do not
penetrate the wires and cause a malfunction.
NOTE
: If wires must be lengthened or spliced
into pre-wired installation, use wire nuts or
other suitable connectors.
Pass wires from safety sensors through wire guide tube on left side of opener front panel and out
through opening at terminal block. Cut wires to length about 2 inches below terminal block opening
being sure wires are not pulled tight.
Strip about 1/2 inch of insulation from end of wires using a wire stripper.
Be sure wire is not nicked while stripping insulation.
Pair two white wires and two white/gray wires together.
Safety sensor wires are inserted into left side holes of terminal block.
Using a small screwdriver depress orange tab above
terminal block hole, insert paired white wires fully to
insulation in one hole and release tab.
Test connection by gently pulling on wire to be sure
it is secure. Install paired white/gray wires in
remaining hole and test connection.
Pull wires gently up guide tube and fold
into opening above terminal block.
Keep wires to the left.
18
Solid white
Color
White/gray
Color
OBS
PB