LION I/O Modules
▪
Product Description
38
▪ Varistor/Suppressor diode – protection against overvoltage (surge), inductive
cut-off voltage
▪ Switching mechanism for short circuits/overload and overtemperature
7.2
Product Overview
Abb. 36: Module Overview
7.3
General Technical Data
1
X30: L-Bus
2
interface, incoming bus, female connector IDE, 14-pin
2
X10: Push-In terminal for input signals
3
X11: Push-In terminal for output signals
4
X31: L-Bus
2
interface, outgoing bus, female connector IDE, 14-pin
5
Module status LED (LB, MS)
6
I/O status LED – outputs
7
X21: Push-In terminal for output signals
8
X0: PE contact
9
X20: Push-In terminal for input signals
10
I/O status LED – inputs
LB
MS
I9
I1
I3
I4
I5
I6
I
7
I8
Q4
I
GND
B
Q4
O
I2
I11 I12 I13 I14 I15 I16 GND
D
I10
I10
I9
Q5
I12
I11
Q6
I14
I13
Q7
I16
I15
Q8
I2
I1
Q1
I4
I3
Q2
I6
I5
Q3
I8
I7
Q4
LION SAFE DI/DO
X10
X11
X20
X30
X 1
3
GND
A
GND
C
Q3
O
Q3
I
Q2
G
Q2
O
Q2
I
Q1
G
Q1
O
Q1
I
Q5
O
Q6
I
Q6
O
Q6
G
Q7
I
Q7
O
Q8
I
Q8
O
Q5
G
X21
Q5
I
1
2
3
4
5
6
1
0
7
8
9
To get detailed technical data of the modules, download the data sheets on
www.luetze-transportation.com
or scan the QR code on the product label or
below.
Mechanics
Housing
aluminium, anodized
Mounting
DIN rail mounting TS35