User Manual LOCC-Box-Net, LOCC-Pads
22
LOCC-Box-Net_1.61_HB_EN
3.5.2 Windows – All Nodes
With this option it is possible to switch all modules ON and
OFF at the same time.
Confirm the security query by clicking Yes to start the
procedure or with No to abort it.
Nodes which are switched off manually cannot be activated
with this function. These nodes can only be switched ON/OFF
in the field LOCC-Box Status( see chapter 3.5.3) or alternately
via the On/OFF button on the modules.
3.5.3 Windows - LOCC-Box Status
The following status and information are only related to the
marked module. The represented lights show the condition of
the status display of the module. The numbers in the field Inom
and Characteristic showing the settings of the current range
and the characteristic curve. The adjacent output voltage and
the currently flowing current are indicated in the field U[V] or
I[A]. The bar Ratio represents the chronological sequence of 0
– 100% of the load monitoring according to the current flow.
This means the bigger the over current, the smaller the time
until the LOCC-Box-Net switches off the load.
On / Off
Provides the possibility to switch the modules ON/OFF or
acknowledge the modules after Blown.
Modules which are switched off manually can only be switched on
after confirming the security query with OK.
3.5.4 Windows - LOCC-Box Characteristic
This field shows the parameters of the selected modules for the adjusted
characteristic curve or rather the current range. Modifications by turning the
selection switch Current Range or Characteristic are only updated after a
restart of the module. The switch off / switch on can occur by the remote input,
the software or by the module button.
Under Extra > LOCC-Box Characteristic
it is possible to program a characteristic
curve and to send it to position 10
(Characteristic) on the LOCC-Box-Net.
Besides that option it is possible to save
and open the characteristic curves. By
modifying the 4 parameters speedy or
lethargically characteristic curves are
possible.
The shown diagram is for better
comprehension of the possible settings.
The diagram is not adapted to the
adjustments.