User Manual LOCC-Box-Net, LOCC-Pads
20
LOCC-Box-Net_1.61_HB_EN
3.5.1 Window - LOCC-Box Nodes (Node Number Assignment)
This window offers the possibility to search modules, to adjust the start/stop record of the module data
and the scan time. Also the node number, the device status, the type, the serial number and an
editable comment are displayed.
Searching new modules with node number 0 (delivery status)
Modules with default settings always have the node number 0. To
use the modules they have to be assigned by a node number
between 1 and 254.
After clicking Search, the internal bus is checked for
connected modules. After the check the message Found
new nodes... appears.
To configure those nodes click Yes, to cancel click No.
If choosing Yes all found modules are in the configuration
mode.
The modules are flashing green. As a standard number 1 is
suggested.
The number can be changed to any other number. To assign
any module to that number press the push button of that
module for 1 sec. The displayed number increments by 1 and
the next module can be assigned. This process has to be
repeated till all modules are assigned to a node number.
Assigned modules can be reset by choosing Extra > LOCC-Box Reset. See
chapter 3.5.11.
An additional Reset of the default status is possible over the push button. See
chapter 2.1.4.
Searching modules with a node number > 0
After clicking Search, the internal bus is checked for
connected modules. All modules with a node number
between 1 and 254 will be displayed in the LOCC-
Box Node window.
Modules with the node number 0 or the same node
number are also recognized. These modules have to
be configured.
The window Search Node appears.
In the following example two modules with the node number 6 were
found.
After configuring node number 7 the search restarts.
This process will be repeated till all modules are
assigned to a valid node number (accept 0).