29
Care and Maintenance
Regular Preventive Maintenance
Perform the following regular preventive maintenance procedures:
CATEGORY DESCRIPTION
TIMELINE
Transformer
Tighten all terminal lugs.
Annually
Blow out all bugs and webs.
Annually
Luminaires
Clean dirty lenses to minimize calcium deposits.
Annually
Straighten all pathway lights.
Quarterly
Trim all plant material as needed; relocate luminaires as needed as plant materials mature.
Quarterly
Clean debris off well light lenses and grates.
Quarterly
Check cable and cable connectors.
Annually
Rebury cable and connectors that may have crept to the surface.
Semiannually
Check aiming angles.
Semiannually
Check, adjust, and replace all cable and cable ties in trees.
As needed