background image

2 - 52

Cajun P880 Routing Switch Installation Guide

2

your startup configuration, refer to “"Copying Running 
Configuration to Startup Configuration"” later in this section. To 
determine changes you have made to your running configuration, 
you can view and compare your running and startup configuration 
files.

Viewing Your Running Configuration

To view your running configuration:

In the 

CLI Configuration

 section of the Web Agent window, 

click 

Running Configuration

.

Or

In 

privileged mode 

in the Command Line Interface, enter 

show running_config

.

Viewing Your Startup Configuration

To view your startup configuration:

In the 

CLI Configuration

 section of the Web Agent window, 

click 

Startup Configuration

.

Or

In 

privileged mode

 in the Command Line Interface, enter 

show startup_config

.

Viewing Your Script Execution Log File

Each time the startup.txt file or other script runs, a log file is 
generated. Log files contain the data that scripts return. 

To view your script execution log file:

In the 

CLI Configuration

 section of the Web Agent window, 

click 

Script Log File

The Script Execution Log File dialog box opens showing the 
contents of the script execution log file.

Or

In 

privileged mode

 in the Command Line Interface, enter 

show file logfile.txt

.

Содержание CAJUN P880

Страница 1: ...Cajun P880 Switch Installation Guide January 2000 VERSION 1 0 ...

Страница 2: ... substitutions and modifications in the products and practices described in this document Lucent Cajun CajunDocs OpenTrunk P220 P550 P880 CajunView QIP and RealNet are trademarks of Lucent Technologies Microsoft Windows Windows NT Windows 95 Windows 98 and Internet Explorer are trademarks or registered trademarks of Microsoft Corporation in the U S and or other countries Netscape and Netscape Navi...

Страница 3: ...tic Discharge 1 4 Installing the Mounting Shelf 1 5 Installing the Chassis 1 6 Rack Mounting the System 1 6 Installing Removing Power Supplies 1 9 Installing the Power Supply 1 9 Removing a Power Supply 1 11 Removing a Power Supply Filler Panel 1 11 Connecting the Power Supplies 1 12 Installing the Modules 1 13 Installing the Cables 1 14 Recommended Cable Distances 1 15 Installing the Cable Manage...

Страница 4: ... Ports Configuration Dialog Box 2 27 Setting Up SNMP Communities 2 28 Changing the Console Serial Port Settings 2 30 Configuring the Serial Console Port as a TTY Console 2 30 Connecting a Modem 2 31 Configuring the Serial Console Port as a PPP Console 2 31 Regaining Configuration Access to the PPP Serial Port Console 2 33 Configuring Dial Up Networking 2 33 Using Dial Up Networking with a PPP Seri...

Страница 5: ...ng Configuration Files 2 51 Viewing Your Running Configuration 2 52 Viewing Your Startup Configuration 2 52 Viewing Your Script Execution Log File 2 52 Copying Configuration Files 2 53 Copying Running Configuration to Startup Configuration 2 53 Copying Files 2 53 Viewing the Status of a TFTP Transfer 2 57 Appendix A Compliance and Specification Information Safety A 1 EMI A 1 Power A 1 Operating Ph...

Страница 6: ...vi Cajun P880 Switch Installation Guide ...

Страница 7: ...s Chapter 1 Installing the Cajun P880 Switch Explains how to unpack and assemble your switch Chapter 2 Configuring the Cajun P880 Switch Explains how to perform the initial configuration of your switch create users and configure ports Appendix A Product Specifications Shows the specifications of your switch Index Documentation Feedback If you have comments about the technical accuracy or general q...

Страница 8: ...s additional information about a procedure or topic CAUTION Indicates a condition that may damage hardware or software Convention Represents Examples User Input User entered text To create a new password type store password owl Emphasis A new term text emphasis or a document title The system settings are permanently saved to NVRAM if you use the store command Boldface Text Menu command or button n...

Страница 9: ...Documents The following documents provide additional information on supporting Lucent s Cajun Family of products Lucent CajunView User s Guide Describes the installation and use of Lucent s Java based multiswitch element management system Lucent Cajun P550 P220 Switch Operation Guide Describes the configuration and operation of the Cajun P550 P220 switch Reference Documents The following documents...

Страница 10: ... 0 201 56332 0 Contacting Lucent Corporation For information about Lucent Data Networking products and services please consult the Lucent World Wide Web site at http www lucent com If you have any questions please call Technical Support Within the United States 1 800 237 0016 press 0 at the prompt then dial ext 73300 From outside the United States 1 813 217 2425 ...

Страница 11: ...oving Power Supplies Installing Removing Fan Assemblies Verifying the System Components To unpack the system check for the following components Chassis including Power supplies installed in the switch Fan trays Supervisor module installed in the switch Blank faceplates I O modules shipped separately Rack mounting shelf 2 side pieces a brace for the back and hex nuts Cable management bracket Cable ...

Страница 12: ...rt any lost or damaged items to your shipping carrier or Lucent representative CAUTION This unit has more than one power supply cord Disconnect all power cords BEFORE servicing to avoid electric shock French Attention Cet appareil comporte plus d un cordon d alimentation Afin de prévenir les chocs électriques débrancher tous les cordons d alimentation AVANT le dépannage German Dieses Gerät hat meh...

Страница 13: ...kg 340 lb A fully loaded switch weighs 77 kg 170 lbs At least 2 inches 5 2 cm on either side of the chassis and from the front and rear of the chassis to allow adequate airflow through the chassis Figure1 Figure 1 Air Flow Requirements AC power source s within 2 m 9 ft separate sources on separate circuits if you require maximum fault tolerance Ambient temperature between 0 C and 40 C 32 F to 104 ...

Страница 14: ... tasks 1 Preventing Electrostatic Discharge 2 Installing the Mounting Shelf 3 Installing the Chassis 4 Installing the Power Supply 5 Connecting the Power Supplies 6 Installing the Modules 7 Installing the Cables 8 Installing the Cable Management Bracket 9 Powering On the System 10 Replacing Fan Assemblies Preventing Electrostatic Discharge Protect the modules against damage from electrostatic disc...

Страница 15: ...stallation There are three brackets supplied for the shelf installation shelf pieces and one brace for the rear of the rack To install the shelf 1 Install the mounting shelf Attach the two side shelf pieces to the rack Make sure that each hole on the mounting bracket lines up with a hole on the rail This ensures proper vertical placement in the rack Do not completely tighten the screws 2 Attach th...

Страница 16: ...supervisor three power supplies and no media modules weighs 57 kg 125 lbs The Cajun P880 chassis containing one supervisor three power supplies and 16 media modules weighs 80 kg 175 lbs WARNING Safe rack mount installation requires two people It is recommended that gloves be worn when lifting the chassis To rack mount the system 1 Remove the power supplies from the chassis see Removing a Power Sup...

Страница 17: ...ed by screw icon with the mounting holes on the rack and secure the chassis to the mounting shelf and rack rails screw holes marked with icon using a quantity of ten 10 pan head minimum recommended size screws not supplied Figure 3 Securing the chassis to the Rack 5 Use the tape measure and level to ensure that the chassis is straight and level 6 Install the power supplies see Installing the Power...

Страница 18: ...see Installing the Cable Management Bracket for more information 9 Attach the plastic trim pieces on the front of the chassis Figure 4 line up the trim piece with the ball studs on the chassis the finger pulls turned outward and clip into place Figure 4 Attaching the Trim Pieces Finger Pulls ...

Страница 19: ...apabilities Use Table 1 for the precise power values Installing the Power Supply The Cajun P880 can contain up to three power supplies This procedure describes how to add or replace the power supplies in the unit 1 Carefully remove the supply and power cord from the shipping box leaving the supply in its anti static wrapping Table 1 Power Values for System Devices Device Power Added Used Power Sup...

Страница 20: ...ON OFF switch on the power supply is OFF O 4 Remove the filler panel from the power supply bay You can insert new power supplies into any available bay Figure 6 5 Insert the supply into the chassis and slide it in until it is firmly seated Figure 5 Figure 5 Installing Removing Power Supplies WARNING Support the bottom of the power supply with your free hand 6 Make sure that the power supply is sea...

Страница 21: ...pull straight out of the chassis 4 Slowly remove the supply from the chassis WARNING Support the bottom of the power supply with your free hand Removing a Power Supply Filler Panel To remove a filler panel 1 Unfasten the captive screw securing the filler panel 2 Grasp the filler panel at the bottom and pull up and forward Make sure all open slots have a filler panel to maintain EMI FCC integrity F...

Страница 22: ... screws tightened Make sure that all of the ON OFF switches on the power supplies are OFF O If you are using multiple power supplies to ensure redundancy make sure that there is a dedicated power circuit available for each supply The separate power sources help ensure operation when the power source itself fails To connect the power supplies 1 Plug the power cord into each power supply Figure 5 2 ...

Страница 23: ...rapping 2 After taking appropriate antistatic precautions as described in Preventing Electrostatic Discharge earlier in the chapter carefully remove the module from the antistatic wrap 3 Open the Ejector Tabs until the stops make contact with the face plate Figure 7 Figure 7 Installing Modules 4 Insert the module into the chassis Figure 7 5 Push on the center of the module pushing it into the chas...

Страница 24: ...d to maintain EMI integrity Installing the Cables Install appropriate cables for your network configuration P880 Cajun switch cable types include Fiber cables with SC type connectors Straight through Category 5 cables with male RJ 45 connectors end station NIC network interface card card connections All I O ports are crossed over internally so you can use straight through cables to attach to end s...

Страница 25: ...o DMD distortion be sure to use Offset Cabling Pinout to 10Base T Cables Pinout for RS 232 DB 9 Female Console Port Pin Signal Description Pin Signal Description 1 Receive data 1 DCD output 2 Receive data 2 TX output 3 Transmit data 3 RX input 4 Not used 4 DTR input 5 Not used 5 SGD ground 6 Transmit data 6 DSR not used 7 Not used 7 RTS not used 8 Not used 8 CTS output N A N A 9 RI not used Standa...

Страница 26: ... you must also consider maximum network diameter which is not discussed in this document Table 4 Maximum Fiber Link Distances for 100 Mb s Links Fiber Cable Description Maximum Cable Length Half duplex connection 412 m Full duplex connection 2 km Table 5 Maximum Copper Cable Lengths 10 100 Mb s Links Cable Description Maximum Cable Length Category 5 twisted pair cable 100 m ...

Страница 27: ...he right side of the chassis To install attach the Cable management bracket 1 Remove the plastic piece from the right side of the chassis 2 Line the bracket up with the ball studs and screw holes and push until it locks into place Figure 9 3 Tighten the captive screws Figure 9 Installing the Cable Management Bracket 4 Thread the cables through the bracket to secure ...

Страница 28: ...fans mounted on the lower rear panel to cool the switch elements Both fan assemblies are hot swappable and contain fan management circuitry to Provides power to the fans Supplies reduced voltage to the fans for reduced speed operation Provides the Fan OK and present status signal to the CPU Forces full fan speed operation in the event of a fan failure Accepts a control signal from the CPU to force...

Страница 29: ...rews and pull the fan assembly towards you Figure 10 3 Remove the fan tray from the chassis 4 Insert the new fan tray into the chassis and slide it into place Note Please be sure that the Pawl latches are not positioned in the locking position the nine o clock position 5 Make sure that the fan tray is seated firmly and tighten the captive screws Figure 10 Installing Chassis Fan Assemblies ...

Страница 30: ... of the chassis 2 Grasp the two top screws on the panel and pull towards you Figure 11 3 Remove the fan tray from the chassis 4 Insert the new fan tray into the chassis fans facing up and slide it into place 5 Make sure that the fan tray is seated firmly and tighten the captive screws Figure 11 Installing Rear Fan Assemblies Captive Screws Captive Screws ...

Страница 31: ...e redundant modules and enable module redundancy 1 Turn power off and unplug the Cajun P880 Switch 2 Using a Phillips head screwdriver loosen the captive screws on the rear panel 3 Carefully pull the rear panel away from the chassis 4 Carefully remove the Switch Element or Switch Controller card from the shipping box 5 In order to take appropriate antistatic precautions plug your ESD strap device ...

Страница 32: ...il they click to lock the card into place 8 To remove a card squeeze Ejector Locking Tabs and pull outward Once the card releases pull it carefully toward you until it clears the guide 9 Replace the rear panel of the switch You will feel slight resistance as you push the panel into place 10 Re insert the rear panel and tighten the captive screws 11 Restart the Cajun P880 Switch and log in See Conf...

Страница 33: ...s When the system has completed running its internal diagnostics the 8 character LED display should read Cajun v4 1 x or later version The LEDs should function as described in Interpreting Front Panel LED Displays in the Cajun P550 P220 Switch Operation Guide In general you will observe the following on properly functioning modules Table6 Table 6 Power up LED Function Module LED Normal Behavior Al...

Страница 34: ...02 1d spanning tree compliant bridge All ports are assigned to a single VLAN virtual local access network All ports can send traffic to all other ports in the system without using a router The system is a single flood domain so all broadcast multicast and unknown unicast traffic will be forwarded to all ports in the system ...

Страница 35: ...sing the Web Agent Configuring System Information Managing Configuration Files Overview The Cajun P880 is a 17 slot chassis that supports Cajun 50 Series and 80 Series media modules 50 Series Mode The Cajun P880 supports Cajun 50 Series and 80 Series media modules when in the 50 Series mode In this mode the P880 is configured as a 16x16 crossbar switch and provides the following performance and sl...

Страница 36: ...r switch and provides the following performance and slot port density 139 Gbps Backplane Switching Capacity 106 Mpps Switching 106 Mpps Routing 17 usable slots 768 10 100Base TX ports autosensing 384 100Base FX ports 128 Gigabit Ethernet ports In both 50 Series and 80 Series modes of operation the Cajun P880 offers Increased port density N 1 switch fabric redundancy N 1 power supply redundancy Hot...

Страница 37: ...r to Switch Features earlier in this guide for pinout information 2 Run a terminal emulation program HyperTerminal for example on the attached PC Ensure that the terminal settings match those listed in Table 7 3 Power up the switch by turning on the power supplies In the terminal emulation program the switch displays the following startup messages Booting the operational system please wait Initial...

Страница 38: ...eserved by Lucent Technologies Corporation This software is furnished under a license and may be used in accordance with the terms of such license and with the inclusion of the above copyright notice This software or any other copies thereof may not be provided or otherwise made available to any other person No title to and ownership of the software is hereby transferred Contains software develope...

Страница 39: ... command configure This changes the command mode to configure mode so that you can use the setup command 8 Enter the command setup This initiates a series of queries Answer each query as follows a When prompted to change the super user password press Enter to accept the default answer of Yes b Enter your old password The system then prompts you for a new password The default password is root c Ent...

Страница 40: ...is the default answer for each questions To accept the default press ENTER Would you like to change the super user password Yes Y Old Password xxxx New Password xxxx Re type New Password xxxx What do you want the switch manager s console Ethernet IP Address to be 192 168 39 40 What is the subnet mask for your network s IP address 255 255 255 0 What is the IP address of the default gateway for this...

Страница 41: ...hapter Configuring the Switch Using the Web Agent The switch includes an embedded HTTP server that enables you to set all the switch s parameters Use this interface for quick and simple configuration changes Refer to the Cajun P550 Manager User Guide for information on monitoring and configuring the Cajun switch using the Cajun P550 Manager interface Figure 15 Cajun P880 Switch Web Agent Applicati...

Страница 42: ...s 4 Click Login The Username Password dialog box opens 5 Enter a valid user name The default super user name is root 6 Enter a valid password The default password is root The Web Agent window opens Note Change the root password for the system as soon as possible to optimize security Setting Up User Accounts User accounts set up in the system allow you to access both the command line interface and ...

Страница 43: ...uide the system s physical layer interaction for example enable disable speed auto negotiation Switch port parameters Enables you to specify how the port participates in switching for example VLAN mode trunking The sections that follow explain how to configure these ports Table 8 User Account Access Levels User Level Can Cannot User READ_ONLY View switch configuration settings and statistics View ...

Страница 44: ... Refer to Table 9 for more information on the Gigabit port parameters 6 In the Name field enter a port name 7 If this is an end station port from the Category pull down menu select User Port For trunk ports select Service Port 8 From the Flow Control Mode pull down menu select Enable to use flow control to prevent buffer overflows Disable this feature only when flow control is causing congestion i...

Страница 45: ...ry Enables you to select either User Port or Service Port The User Port is intended for use with switch connections to end user nodes The Service Port is intended for use with switch connections to servers or other switches The primary difference between the User and Service Port designation is that a Service Port allows the switch to generate both log messages and alarm messages traps The User Po...

Страница 46: ...rameters The Detailed Physical Port Configuration dialog box opens Refer to Table 10 for more information on the Fast Ethernet 10 100 parameters 6 In the Name field enter a port name Port PACE Priority Determines if the port detects 3Com s copyrighted PACE format as packets pass through the port PACE allows a packet s priority higher priority packets move through the switch faster to be set at the...

Страница 47: ...tes as well If you are having problems with auto negotiating connections try setting the modes manually using the command line interface For example set port auto 7 3 enable 12 From the Auto Negotiation Speed Advertisement and Auto Negotiation Duplex Advertisement pull down menus set Speed and Duplex Advertisement respectively The switch sends these values to the device on the other end of the con...

Страница 48: ...device connected to the port Category Allows you to select either User Port or Service Port The User Port is intended for use with switch connections to end user nodes The Service Port is intended for use with switch connections to servers or other switches The Service Port allows the switch to generate both log messages and alarm messages traps The User Port only generates log messages preventing...

Страница 49: ... on the other end of the link is set to auto negotiate as well If you set a port to auto negotiate and the connection is not successful set the port speed and duplex mode manually Auto Negotiation Speed Duplex Advertisement Determines what information the port advertises when it starts auto negotiating In most cases 10 100 and Half Full are the best settings but there may be cases when you want to...

Страница 50: ...ts Configuration dialog box opens 4 Set port parameters as described beginning in Configuring Physical Port Parameters on Gigabit Ports earlier in this chapter 5 Click APPLY to save your changes or CANCEL to restore previous settings Rate Limit Burst Size Determines the limit of packets allowed in a single burst Accepted values are 1 to 2048 For Fast Ethernet ports set this value lower than 1024 o...

Страница 51: ...ion Links Opens associated dialog boxes Port Displays the port name associated with the selected module Name Displays the port name and opens the Switch Port Configuration dialog box for the selected module Port VLAN Displays the port VLAN for the selected module VLAN Classification Displays the port VLAN classification for the selected module Trunk Mode Displays the port s trunk mode for the sele...

Страница 52: ... each port performs switching functions for example VLAN parameters hunt group assignments trunk mode and frame tag scheme Refer to Table12 for more information on individual switch port configuration parameters To configure switch port parameters 1 In the System Configuration section of the Web Agent window select Modules Ports The Module Information dialog box opens 2 From the Model Number colum...

Страница 53: ...Port Configuration Parameters Parameter Definition Port VLAN Specifies the VLAN assignment for this port Trunk Mode Select the trunk mode Allows you to define the port as a trunk and allows you to select the appropriate VLAN trunking format if the port is connected to another switch Refer to Table13 for more information on trunk mode options Frame Tags Select whether to ignore or use received Fram...

Страница 54: ...g of new addresses The default is Enable Hunt Group Select a hunt group for which this port will be a member The default is None Spanning Tree Mode Select to enable or disable spanning tree protocol on this port The default is Enable Fast Start Select to enable or disable fast start on this port The default is Disable Known Mode Select to enable or disable known mode The default is Disable 3Com Ma...

Страница 55: ...signed to the specified VLAN The port will still assign incoming tagged packets to the VLAN indicated by the tag 2 From the Trunk Mode pull down menu select the option excluding Clear to indicate that the port is a trunk and to select the appropriate VLAN trunking format if the port is connected to another switch Table 13 describes the VLAN Trunking Mode options 3 From the Frame Tags pull down men...

Страница 56: ... VLANs known to the switch This is an appropriate mode for switch to switch connections If you use 3Com Mapping Tables this setting is ignored Note When a tagged IEEE 802 1Q packet arrives on a port that is set to bind to all and the VLAN does not exist on the switch the packet is forwarded on to the VLAN assigned to the port default VLAN for that port To prevent unintended forwarding of unknown V...

Страница 57: ...to disable its ability to learn VLAN changes on the network s Cisco VTP server To configure switch port VTP Snooping parameters 1 In the System Configuration section of the Web Agent click Modules and Ports The Module Information dialog box opens 2 In the Switch Ports column click on the Switch Ports link for the module which you want to enable VTP snooping The Switch Ports dialog box for that mod...

Страница 58: ...egate Bandwidth between Switches in the Cajun P550 P220 Switch Operation Guide for more information on hunt groups Table 15 VTP Snooping Parameters Parameter Definition VTP Snooping State Select to enable or disable the VTP snooping protocol globally for the switch The default value is Disabled Domain Name Enter the name associated with the Cisco VTP domain The default is Null Note The domain name...

Страница 59: ...Mapping Table pull down menu select an assignment to specify how incoming tagged frames from 3Com equipment are mapped to Lucent VLANs Refer to Creating 3Com Mapping Tables in the Cajun P550 P220 Switch Operation Guide for more information on 3Com Mapping Tables 7 Click APPLY to save your changes or CANCEL to restore previous settings Examples of Switch Ports Settings for Various VLAN Connection T...

Страница 60: ...n using 3Com VLANs Trunk Mode 3Com Allows the switch to read the incoming VLAN tags VLAN Binding Static This parameter is ignored when using 3Com VLANs Automatic VLAN Creation Disable This parameter is ignored when using 3Com VLANs Table 18 Example 3 Trunk to Bay Networks System 5000TM Parameter Recommended Setting Port VLAN Default Causes untagged packets to be assigned to the default VLAN Trunk ...

Страница 61: ... From the Fast Start pull down menu select Enable to enable Fast Start mode on the selected module ports 5 Click APPLY to save your changes or CANCEL to clear your selection Using the All Ports Configuration Dialog Box The All Ports Configuration dialog box allows you to apply the same parameter settings to all switch ports in a module using a single command To set all switch ports in a module usi...

Страница 62: ...u select Any for any IP address or Specific and enter an IP Address in the appropriate fields Table 19 SNMP Communities Parameters Parameter Definition Community String This string serves as a password that you enter at the network management station It provides the level of access to the switch that you specify on this page IP Address Allows you to send SNMP responses only to a station with any o...

Страница 63: ... View switch configuration settings and statistics View community strings Change switch configurations Read Write View and set switch configuration settings and view statistics View community strings Read Write with Security Level Set to admin View and set all switch parameters including community table N A None Do nothing This selection allows you to disable a string without deleting it Access an...

Страница 64: ...ameters The flow control parameters are limited to None or Xon Xoff Configuring the Serial Console Port as a TTY Console To configure the console serial port as a TTY Console 1 In the System Configuration section of the Web Agent window select Console Configuration The Console Configuration dialog box opens 2 Click TTY for your console type and click SELECT The Console Port Configuration dialog bo...

Страница 65: ...d to the modem DCD output to detect that the modem is connected It supports XON XOFF flow control or none To connect a modem 1 Attach a DB25M RJ45 P N 38210003 connector to the modem 2 Attach the DB9M RJ45 MDCE connector to the switch s serial console port on the front panel of the switch Figure 17 Typical Connection Between the Switch and a Modem Configuring the Serial Console Port as a PPP Conso...

Страница 66: ...d enter your modem initialization command The default modem configuration string is AT D0S0 1 5 Click APPLY to save your changes or CANCEL to restore previous settings Note If you misconfigure your PPP serial console port you can regain CLI access to correct the configuration parameters For more information refer to Regaining Configuration Access to the PPP Serial Port Console Safety Tip To succes...

Страница 67: ...P Interface in Chapter 7 for more information on PPP configuration commands 5 After you complete your configuration settings type exit at the CLI prompt to reinvoke the modem control software and exit CLI mode Note You do not need to exit from CLI if the serial port console has been configured as a TTY console or if you do not intend to re attempt connecting using PPP Configuring Dial Up Networkin...

Страница 68: ...rd dialog box click Next and enter the telephone number you are calling 13 Click Next The wizard reports that you have successfully configured a modem 14 Click Finish The wizard closes and the newly configured connection displays in your Dial Up networking program group 15 Right mouse click on your new connection and select Properties The Properties dialog box opens 16 Click the Server Types tab a...

Страница 69: ...low the CLI prompt This is typical while the switch attempts to connect via PPP 6 In the Post Dial Terminal screen click Continue F7 PPP verification completes and the Connected To dialog box displays a message that the modem connection has been successfully established Configuring the IP Interface for the PPP Console To configure the PPP console with an IP address and mask 1 Configure your consol...

Страница 70: ...IP Static Routes dialog box opens This allows you to define a static route for the PPP console 4 In the Network Address field enter the IP address to be associated with the PPP console port 5 In the Mask field enter the network mask IP address 6 In the Next Hop Address field enter the IP address of the gateway associated with this static route 7 Click APPLY to save your changes or CANCEL to restor...

Страница 71: ...hich interfaces need to have IP routing enabled If you plan to expand your current network create VLANs subnets to address your network configuration Assign an IP address subnet mask routing protocol and multicast routing protocol to each IP interface you configure Routing Configuration Quickstart This section provides an overview of the LAN router configuration operation For more information on t...

Страница 72: ...s Displaying Cooling System Statistics Performing a System Reset Configuring Redundant Hardware Entering General System Information The system allows you to enter general system identification information from the Web Agent Use these fields to uniquely identify each switch Switch name Device location Device contact To change these values 1 In the System Information section of the Web Agent window ...

Страница 73: ...efer to Setting One Time Summer Time Hours For information about setting Summer Time Hours refer to Setting Summer Time Hours To enable SNTP 1 In the System Information section of the Web Agent window click System Clock The System Clock dialog box opens 2 In the Clock Options section click Simple Network Time Protocol SNTP The SNTP Client Configuration dialog box opens 3 From the Enable State pull...

Страница 74: ...me values Ensure that you change the Summer Time Hours Algorithm before you set the clock Setting Recurring Summer Time Hours To set recurring Summer Time Hours 1 In the System Information section of the Web Agent window click System Clock The System Clock dialog box opens 2 In Clock Options click Summer Time Hours Algorithm The Summer Time Hours Configuration box opens 3 From the Enable State pul...

Страница 75: ... and end Start Specifies the start of Summer Time Hours End Specifies the end of Summer Time Hours Week Select the week during which you want recurring Summer Time Hours to start or end The selected week should reflect the day on which Summer Time Hours start For example if Summer Time Hours start on the first Sunday in April select the First week Options include First First week of the month the ...

Страница 76: ...y Saturday Month Select the month when recurring Summer Time Hours start or end The twelve months of the Gregorian calendar are provided For recurring Summer Time Hours the default Start value is April the month during which DST starts in the Western hemisphere The default End value is October the month during which DST ends in the Western hemisphere Hour Enter a value to represent the hour when S...

Страница 77: ...the clock in minutes For example if you intend to reset the clock forward or backward by one hour retain the default value of 60 minutes 5 Click One Time Note The Web Agent enables you to select the boxes next to both Recurring and One time Summer Time Hours However the option to set both Recurring and One time hours is not provided 6 Use Table25 to configure Summer Time Hours on a one time basis ...

Страница 78: ...Options are based on a seven day week and include Sunday The default Start and End values In the Western hemisphere DST starts on the first Sunday in April and ends on the last Sunday in October Monday Tuesday Wednesday Thursday Friday Saturday Month Select the month when one time Summer Time Hours start or end The twelve months of the Gregorian calendar are provided For a one time setting of Summ...

Страница 79: ...for setting traps alarms and other events of the switch Set SNTP and Summer Time Hours before you set the system clock To set the system clock 1 In the System Information section of the Web Agent window click System Clock The System Clock dialog box opens 2 In the Current Time Setting fields enter the time using 24 hour time format for example 10 p m is 22 00 00 3 From the Time Zone pull down menu...

Страница 80: ...ing modules if the temperature reaches the Shutdown temperature The modules are restarted if the temperature goes below the Upper Warning Temperature The default Shutdown temperature for the slot 1 sensor and backplane sensor is 50 C You can set the warning temperature to a value lower than 50 C to ensure prompt notification of an over temperature situation Displaying the Power System Statistics T...

Страница 81: ...ystem Information section of the Web Agent window click Cooling System The Cooling System dialog box opens 2 Ensure that all the individual components are operational by checking the status column for each component 3 If a component s status is non operational power down the Caju P880 Switch and contact a service representative to diagnose the failing unit Configuring Redundant Hardware The Cajun ...

Страница 82: ... hardware In the Web Agent information about a failed controller or element displays in the Switch Fabric Status dialog box If the primary controller fails the redundant controller takes over switch operation until you replace the primary controller If an element fails the redundant element takes over the function of the failed element until you replace the element Checking for Proper Installation...

Страница 83: ...ontroller If the primary controller fails you are notified by a console message and an event log message In the Web Agent the Switch Controller field displays 0 Failed If the switch is installed with a redundant controller the redundant controller automatically takes over the operation of the failed primary controller To replace the primary controller 1 In the System Information section of the Web...

Страница 84: ...ller is now enabled 10 In the Toggle Active Controller field click Toggle to restore control to the primary controller The Switch Controller field displays 0 Active to show that the primary controller is now enabled Replacing an Element If an element fails you are notified by a console message and an event log message In the Web Agent the Switch Elements field displays Failed number where number i...

Страница 85: ... Reset The System Reset Page dialog box opens 2 Click Save to save your running configuration to the startup configuration before performing a system reset 3 Click Yes to reset the switch or No to cancel the operation Managing Configuration Files You can manage the system files that contain the configuration data for your Cajun P880 switch When you first install the switch or upgrade from a previo...

Страница 86: ... show running_config Viewing Your Startup Configuration To view your startup configuration In the CLI Configuration section of the Web Agent window click Startup Configuration Or In privileged mode in the Command Line Interface enter show startup_config Viewing Your Script Execution Log File Each time the startup txt file or other script runs a log file is generated Log files contain the data that...

Страница 87: ...e your running configuration as your startup configuration in NVRAM 1 In the CLI Configuration section of the Web Agent window click Config File Management 2 Click Save to save your running configuration as your startup configuration Or In privileged mode in the CLI enter copy running config startup config Copying Files Using the Configuration File Management dialog box you can copy files to and f...

Страница 88: ... N A Copy Source Specifies the source file to be copied Unspecified No source specified Choose a source File Specifies a source file located on the switch in NVRAM Running Config Specifies a running configuration Startup Config Specifies a startup configuration TFTP Server Specifies a source file located in a directory on a TFTP server Source Filename Specifies the path and name of the source file...

Страница 89: ...t a source is copied to a TFTP server location Destination Filename Specifies the location of the destination Configuration files and other files can be copied to NVRAM on the switch or to a TFTP server as a destination location TFTP Server IP Address Specifies the IP address of a source or destination TFTP server Copy download source files located on a TFTP server to your running configuration yo...

Страница 90: ...lename field 4 From the Copy Destination pull down menu select one of the following Running Config If you are copying your startup configuration or other file located on the switch or on a TFTP server to your running configuration Startup Config If you are copying your running configuration or other file located on the switch or on a TFTP server to your startup configuration File If you are copyin...

Страница 91: ...fied TFTP server to a TFTP server Viewing the Status of a TFTP Transfer After you have copied the startup configuration or other files to a TFTP server you can check the status of the TFTP transfer to ensure that files copied correctly To view the status of a TFTP transfer 1 In the CLI Configuration section of the Web Agent click Config File Management The Configuration File Management dialog box ...

Страница 92: ...2 58 Cajun P880 Routing Switch Installation Guide 2 ...

Страница 93: ...No 950 IEC 950 TUV GS EMI FCC 15J Class A CE Mark EN55022 Class A CISPR 22 Class A EN55024 Power AC input voltage 100 240 VAC 6 10 Frequency 50 60 Hz Maximum Power Consumption Per Power Supply 10 0 A 120 V 5 5 A 240 V Line cord connector to power supply must be IEC320 C15 Cordage must be sized appropriately for rated current ...

Страница 94: ...ng Switch Installation Guide Operating Physical Operating Temperature Sea Level 0 to 40 C Storage Temperature Sea Level 20 to 80 C Relative Humidity 5 to 95 noncondensing Physical Dimensions 17 375 W x 18 5 D x 25 H 15 RU ...

Страница 95: ...r logins 2 8 user name 2 9 admin SNMP security level 2 29 airflow installation 1 3 all module ports configuration 2 16 all ports configuration gigabit ports 2 10 allow learning non VLAN switch port parameters 2 24 switch port configuration para meters 2 20 anti static wrapping power supplies 1 9 assignment Virtual LANs configuring 2 21 Audience of Manual ix auto negotiation speed duplex advertise ...

Страница 96: ...flow control mode gigabit module 2 10 configuring physical port parameters gigabit ports 2 11 configuring port name Fast Ethernet module 2 12 configuring port VLAN parameters 2 21 configuring service port gigabit module 2 10 configuring the PPP console static route 2 36 configuring the serial port console PPP console 2 32 configuring the temperature system 2 46 configuring user port gigabit module...

Страница 97: ...ion 2 38 Ejectors 1 14 electrostatic discharge preventing 1 4 Electrostatic Discharge ESD 1 4 enabling controller redundancy 1 21 enabling fast start mode for all ports on a module 2 27 enabling fast start mode for individual ports 2 27 enabling gigabit ports 2 10 2 12 enabling SNTP 2 39 enabling the rate limit mode Fast Ethernet module 2 13 end one time summer time hours configuration 2 43 summer...

Страница 98: ...n 2 44 summer time hours configuration 2 42 hunt group non VLAN switch port parameters 2 24 switch port configuration para meters 2 20 switch port parameter 2 17 I IEEE 802 1Q Virtual LAN trunking mode 2 21 installation airflow 1 3 cable distances 1 15 cable types 1 14 connecting th power supplies 1 12 location 1 3 power supplies 1 9 powering on the system 1 23 preventing electrostatic discharge 1...

Страница 99: ... 25 normal SNMP security level 2 29 O one time summer time hours configuration 2 43 day 2 44 end 2 43 hour 2 44 minutes 2 44 month 2 44 start 2 43 week 2 44 Online documentation viii Out of Band connection kit 1 2 P parity console serial port settings 2 30 performing a system reset 2 51 port switch port parameter 2 17 Port LED 1 23 port name configuring switch port parameters 2 18 gigabit port par...

Страница 100: ...ng summer time hours configuration 2 41 redundant controllers installing 1 21 redundant element configuring 2 50 related documents ix relative humidity installation 1 3 remote fault detect gigabit port parameters 2 12 remote fault detection 2 10 removing filler panels 1 11 power supplies 1 11 replacing the primary controller 2 49 routing hardware requirements 2 36 Layer 3 switching 2 37 routing co...

Страница 101: ...ng options 2 22 static route PPP console 2 36 status power system statistical parameters 2 46 stop bits console serial port settings 2 30 Straight through RJ 45 Cable 1 2 summer time hours one time setting 2 43 set recurring 2 40 setting 2 39 summer time hours configuration day 2 42 end 2 41 hour 2 42 minutes 2 42 month 2 42 recurring 2 41 start 2 41 week 2 41 supported browsers 2 8 switch configu...

Страница 102: ... rate 2 30 data bits 2 30 flow control 2 30 parity 2 30 stop bits 2 30 TX LED 1 23 type power system statistical parameters 2 46 U Unpacking 1 1 update timestamp VTP snooping parameters 2 24 updater identity VTP snooping parameters 2 24 updater time stamp VLAN exchange parameters 2 24 user account access level ADMINISTRATOR user 2 9 READ_ONLY user 2 9 READ_WRITE user 2 9 user accounts access level...

Страница 103: ...e parameters updater timestamp 2 24 VTP snooping Cisco Catalyst 5000 parameters 2 25 configuring 2 23 VTp snooping switch port configuration para meters 2 20 VTP snooping parameters configuration revision number 2 24 domain name 2 24 update timestamp 2 24 updater identity 2 24 VTP snooping state 2 24 VTP snooping state VTP snooping parameters 2 24 W Web Agent logging in 2 8 setting up user account...

Страница 104: ...10 Cajun P880 Switch Installation Guide ...

Отзывы: