Cajun P880 Routing Switch Installation Guide
2
CAUTION
Before replacing switch controllers or elements, you must
turn off the switch.
5.
Replace the failed primary controller by inserting it in the slot to
the right of the redundant controller and to the left of element
three.
6.
Restart the switch and login.
7.
In the
System Information
section of the Web Agent, click
Switch Fabric
. The Switch Fabric Status dialog box displays.
8.
From the
Configure Redundant Hardware
pull-down menu,
select
Yes.
9.
Click
APPLY
to enable the redundant controller.
The Switch Controller field displays # 1 Active to show that the
redundant controller is now enabled.
10.
In the
Toggle Active Controller
field, click
Toggle
to restore
control to the primary controller.
The Switch Controller field displays # 0 Active to show that the
primary controller is now enabled.
Replacing an
Element
If an element fails, you are notified by a console message and an
event log message. In the Web Agent, the Switch Elements field
displays # Failed <number>, where
<number>
is the number that
indicates the failed element.
To configure the redundant element:
1.
In the
System Information
section of the Web Agent window,
click
Switch Fabric
. The Switch Fabric Status dialog box
displays.
2.
From the
Configure Redundant Hardware
pull-down menu,
select
No
.
3.
Click
Apply
to disable the failed element.
4.
Shut down the switch.
CAUTION
Before replacing switch controllers or elements, you must
turn off the switch.