![Lucent Technologies CAJUN P880 Скачать руководство пользователя страница 67](http://html.mh-extra.com/html/lucent-technologies/cajun-p880/cajun-p880_installation-manual_1946437067.webp)
Cajun P880 Routing Switch Installation Guide
2 - 33
Regaining
Configuration
Access to the PPP
Serial Port Console
If the PPP serial port console is configured incorrectly, the command
line interface (CLI) becomes temporarily unavailable for
reconfiguration.
To regain access to the CLI when the console port is in PPP mode:
1.
In the console window, type
TTY
. The CLI login prompt displays.
It may be necessary to press Enter several times to see the login
prompt. You may see the modem init command string.
2.
At the
Login
prompt, enter your
user name
. The password
prompt displays.
3.
At the
Password
prompt, enter your
password
. The Cajun CLI
prompt displays.
4.
Enter the PPP configuration commands necessary to start PPP.
Refer to “Configuring the Serial Console Port as a PPP Console”,
earlier in this chapter, and “Creating an IP Interface”, in Chapter
7, for more information on PPP configuration commands.
5.
After you complete your configuration settings, type
exit
at the
CLI prompt to reinvoke the modem control software and exit
CLI mode.
* Note:
You do not need to exit from CLI if the serial
port console has been configured as a TTY
console, or if you do not intend to re-attempt
connecting using PPP.
Configuring Dial-Up
Networking
To configure your PC for dial-up networking with a PPP serial port
console:
1.
From
My Computer
, double-click
Dial-Up Networking
. The
Dial-Up Networking dialog box opens.
* Note:
You must have dial-up networking installed on
your PC.
2.
Double-click
Make New Connection
to configure your
modem. The Make New Connection wizard opens.
3.
In the
Type a name for the computer you are dialing
field,
enter a
connection name
for the computer you are dialing.
4.
From the
Select a Modem
pull-down menu, select your
modem
and click
Configure
. The Modem Properties dialog box
opens.
5.
Click the
Connection