Cajun P880 Routing Switch Installation Guide
1 - 3
Selecting a Location
The location you select for installing the system hardware must
meet the following requirements:
■
19-inch EIA-standard grounded rack or table capable of
supporting at least 154 kg (340 lb). A fully-loaded switch
weighs 77 kg (170 lbs).
■
At least 2 inches (5.2 cm) on either side of the chassis, and
from the front and rear of the chassis, to allow adequate
airflow through the chassis (
Figure1
).
Figure 1. Air Flow Requirements
■
AC power source(s) within 2 m (9 ft) (separate sources, on
separate circuits, if you require maximum fault tolerance)
■
Ambient temperature between 0°C and 40°C (32°F to 104°F)
■
Relative humidity less than 95%, non-condensing