7.9 Options for AlfaSolar S/SR
™
models
Figure 34: High mounting leg installation (AlfaSolar SR
™
series)
7.9.5 Vibration dampers
The suitability of the elastic vibration dampers supplied by Fincoil LU-VE Oy has been ensured.
Proceed as follows:
1.
Check the load weight and ensure that the correct dampers for this load are available.
Note:
Check the weight distribution on the damping rubber.
2.
Check that the ground and the basement of the unit are horizontal.
The vibration dampers are meant for vertical compression load.
3.
When damping a group of units, place both the driving unit and the operated unit on a rigid basement.
4.
Check the ambient conditions at site:
• Temperature 35 °C … +65 °C
• Organic solvents are injurious
• Oils might damage the rubber parts of the damper
5.
When connecting, for example, tubes to the unit, always use flexible connections.
©
Alfa LU-VE, Rev-04
58
Alfa LU-VE is a trademark registered and owned by LU-VE Group.
Alfa LU-VE reserves the right to change specifications without prior notification.