![LU-VE AlfaSolar S Скачать руководство пользователя страница 57](http://html1.mh-extra.com/html/lu-ve/alfasolar-s/alfasolar-s_instruction-manual_1945293057.webp)
7.9 Options for AlfaSolar S/SR
™
models
Height [m] Description
Availability
4
4 m legs are delivered loose.
SR
Figure 33: Installation of 1m leg extension to AlfaSolar S/SR
™
1.
Slide the extensions over the standard legs.
2.
Install the vertical leg supports with M10 grade 8.8 bolts.
The required M10 bolts, nuts and spring washers are included in the delivery.
Control cabinets with 2 m and 4 m legs are delivered loose. The legs are fitted at ground level.
See separate instructions for installing the AlfaSolar SR
™
series high mounting legs (2 m, 3 m and 4 m legs).
Check the actual wind load and EQ classification from the datasheet.
The amount of legs and support beams depends on the local wind and snow loads and earthquake
classification (special options). For greater environmental loads, the order specific stress calculations with
additional support beams and legs are available.
High mounting legs are part of the machine and according to the EN1090-1 standard, they do not require CE-
marking.
Standard surface treatment: Hot-Dip Galvanized.
All painting options are available according to the painting specification.
©
Alfa LU-VE, Rev-04
57
Alfa LU-VE is a trademark registered and owned by LU-VE Group.
Alfa LU-VE reserves the right to change specifications without prior notification.