![LT Security LTD8316T-ET Скачать руководство пользователя страница 94](http://html1.mh-extra.com/html/lt-security/ltd8316t-et/ltd8316t-et_user-manual_1944728094.webp)
8.7
Setting Alarm Response Actions
Purpose:
Take alarm response actions will be activated when an alarm or exception occurs, including Full Screen
Monitoring, Audible Warning (buzzer), Notify Surveillance Center, Send Email and Trigger Alarm Output.
Full Screen Monitoring
When an alarm is triggered, the local monitor (HDMI, VGA or CVBS monitor) display in full screen the video
image from the alarming channel configured for full screen monitoring.
If alarms are triggered simultaneously in several channels, their full-screen images will be switched at an interval
of 10 seconds (default dwell time). A different dwell time can be set by going to Menu > Configuration > Live
View.
Auto-switch will terminate once the alarm stops and you will be taken back to the Live View interface.
Audible Warning
Trigger an audible
beep
when an alarm is detected.
Notify Surveillance Center
Sends an exception or alarm signal to remote alarm host when an event occurs. The alarm host refers to the PC
installed with Remote Client.
The alarm signal will be transmitted automatically at detection mode when remote alarm host is configured. Please
refer to
Chapter 9.2.6
for details of alarm host configuration.
Send Email
Send an email with alarm information to a user or users when an alarm is detected.
Please refer to
Chapter 9.2.8
for details of Email configuration.
Trigger Alarm Output
Trigger an alarm output when an alarm is triggered.
Steps:
1.
Enter Alarm Output interface.
Menu> Configuration> Alarm> Alarm Output
Select an alarm output and set alarm name and dwell time. Click
button to set the arming schedule of
alarm output.
If “Manually Clear” is selected in the dropdown list of Dwell Time, you can clear it only by going to Menu>
Manual> Alarm.
Figure 8. 17
Alarm Output Settings Interface
2.
Set up arming schedule of the alarm output.
Choose one day of a week and up to 8 time periods can be set within each day.
Time periods shall not be repeated or overlapped.
Available from A1 Security Cameras
www.a1securitycameras.com email: [email protected]
Содержание LTD8316T-ET
Страница 78: ...Chapter 7 Backup Available from A1 Security Cameras www a1securitycameras com email sales a1securitycameras com...
Страница 104: ...Chapter 10 VCA Search Available from A1 Security Cameras www a1securitycameras com email sales a1securitycameras com...
Страница 123: ...Chapter 12 HDD Management Available from A1 Security Cameras www a1securitycameras com email sales a1securitycameras com...
Страница 145: ...Chapter 15 Others Available from A1 Security Cameras www a1securitycameras com email sales a1securitycameras com...
Страница 153: ...Chapter 16 Appendix Available from A1 Security Cameras www a1securitycameras com email sales a1securitycameras com...