Chapter 1 General
1
-
10
1.4.4 Allocation of compact type (S/H type) output signal
(1)
Allocation of output signal
In case of using built-in positioning of XGB compact standard/high-end type main unit, output signal is
allocated as follows.
Signal name
Input contact point no.
Operation content
Reference
Pulse + Direction
mode
CW/CCW mode
Axis
XBC-
DN
□□
H
XBC-
DN(P)
□□
S(U)
XEC-
DN(P)
□□
S(U)/H
Pulse output
(CW output)
X
axis
P00020
P00040
%QX0.0.0
Positioning X axis
pulse string
(Open collector
output)
X axis CW pulse
string output
(Open collector
output)
Low Active and
High Active is
selectable in
parameter
setting
Y
axis
P00021
P00041
%QX0.0.1
Positioning Y axis
pulse string
(Open collector
output)
Y axis CW pulse
string output
(Open collector
output)
Direction
output
(CCW
output)
X
axis
P00022
P00042
%QX0.0.2
X axis direction
output contact
point
(Open collector
output)
X axis CCW pulse
string output
(Open collector
output)
Y
axis
P00023
P00043
%QX0.0.3
Y axis direction
output constant
point
(Open collector
output)
Y axis CCW pulse
string output
(Open collector
output)
External 24V
X/Y
axis
P
Terminal for external power (12/24V) to
implement the transistor
Input
common
X/Y
axis
COM0
Output common terminal
* Standard type (XBC-DN(P)
□□S(U)) supports only “pulse + direction mode”.
(2) Wiring example of external input signal
In case of using positioning function of XGB high-end basic unit, wiring example is as follows.
Содержание XBC-DN20S
Страница 210: ...Chapter 7 Program Examples of Positioning 7 6 2 XEC ...
Страница 215: ...Chapter 7 Program Examples of Positioning 7 11 2 XEC ...
Страница 220: ...Chapter 7 Program Examples of Positioning 7 16 2 XEC ...
Страница 225: ...Chapter 7 Program Examples of Positioning 7 21 2 XEC ...
Страница 232: ...Chapter 7 Program Examples of Positioning 7 28 2 XEC ...
Страница 237: ...Chapter 7 Program Examples of Positioning 7 33 2 XEC ...
Страница 240: ...Chapter 7 Program Examples of Positioning 7 36 ...
Страница 308: ...Appendix 4 Dimension App 4 3 3 High end type main unit XBC DN32H XEC DN32H XEC DP32H XBC DR32H XEC DR32H ...
Страница 309: ...Appendix 4 Dimension App 4 4 XBC DN64H XEC DN64H XEC DP64H XBC DR64H XEC DR64H ...
Страница 311: ...Appendix 4 Dimension App 4 6 XBE DC08A XBE DC16A XBE TN08A XBE TN16A XBE DR16A XBE RY08A ...
Страница 312: ...Appendix 4 Dimension App 4 7 5 Communication module XBL C41 21A XBL EMTA ...
Страница 313: ...Appendix 4 Dimension App 4 8 5 Special module XBF AD04A XBF DV04A ...