Chapter 5 Positioning Instructions
5
-
12
5.2.4 Indirect Starting Instruction
• Indirect starting refers to execution of the positioning operation by using the operation step data set in
the positioning operation data.
(1)
Indirect Starting Instruction (IST)
[
[Area Setting]
Operand
Description
Setting range
Data size
sl
Slot No. of positioning module
XGB is fixed at 0
WORD
ax
Axis to give instruction
0 (axis X) or 1 (axis Y)
WORD
n1
Step number to start
0~30(standard), 0~80(advanced)
WORD
[Flag Set]
Flag
Description
Device number
Error
If the value of ax gets out of the range
F110
(a) Function
• This instruction is giving indirect starting instruction to XGB built-in positioning.
• The indirect starting is executed to the axis designated as ax of XGB positioning at the rising edge
of the input condition.
• If the instruction is executed, the positioning operation is carried out by the operation data set in
the step number of area K designated in n1. If n1 is set at 0, the operation step is executed which
is displayed in the step number of current positioning area K (axis X:K426, axis Y:K436 word).
• Various operation patterns such as end, continued, and incessant operation, and single and
repeated operation can be made and executed by using the indirect operation instruction.
(b) Error
• If the value designated as ax (instruction axis) is other than 0 and 1, the error flag (F110) is set
and the instruction is not executed.
• In this case, execution of instruction is error. so K area error ocurrence Flag(X axis:K4201, Y
axis:K4301) doesn't turn On
• If the set value of the starting step number gets out of the settable range, instruction Error
Flag(F110) is not set, the error flag of positioning area K (axis X:K4201, axis Y: K4301) turns On,
and the operation does not occur.
Instruction
Areas available
Step
Flag
PMK
F
L
T
C
S
Z D.x R.x
con
stan
t
U
N
D
R
Error
(F110)
Zero
(F111)
Carry
(F112)
IST
sl
-
-
-
-
-
-
-
-
-
○
-
-
-
-
4~7
○
-
-
ax
○
-
○
-
-
-
○
-
-
○
-
-
○
-
n1
○
-
○
-
-
-
○
-
-
○
-
-
○
-
IST
COMMAND
IST
sl
ax
n1
Содержание XBC-DN20S
Страница 210: ...Chapter 7 Program Examples of Positioning 7 6 2 XEC ...
Страница 215: ...Chapter 7 Program Examples of Positioning 7 11 2 XEC ...
Страница 220: ...Chapter 7 Program Examples of Positioning 7 16 2 XEC ...
Страница 225: ...Chapter 7 Program Examples of Positioning 7 21 2 XEC ...
Страница 232: ...Chapter 7 Program Examples of Positioning 7 28 2 XEC ...
Страница 237: ...Chapter 7 Program Examples of Positioning 7 33 2 XEC ...
Страница 240: ...Chapter 7 Program Examples of Positioning 7 36 ...
Страница 308: ...Appendix 4 Dimension App 4 3 3 High end type main unit XBC DN32H XEC DN32H XEC DP32H XBC DR32H XEC DR32H ...
Страница 309: ...Appendix 4 Dimension App 4 4 XBC DN64H XEC DN64H XEC DP64H XBC DR64H XEC DR64H ...
Страница 311: ...Appendix 4 Dimension App 4 6 XBE DC08A XBE DC16A XBE TN08A XBE TN16A XBE DR16A XBE RY08A ...
Страница 312: ...Appendix 4 Dimension App 4 7 5 Communication module XBL C41 21A XBL EMTA ...
Страница 313: ...Appendix 4 Dimension App 4 8 5 Special module XBF AD04A XBF DV04A ...