3 Product description
8
|
EN
LM
T
68
54
1a
0
6/
20
21
3.3 Symbols in display
3.4 Accessories (optional)
3.5 Operating states
•
On
: Therapy is in progress. It is possible to make changes
to device and therapy settings.
•
Standby
: The blower is off and therapy is not in
progress. However, the device is ready for operation
immediately. It is possible to make changes to device and
therapy settings.
•
Off
: The device is switched off. No setting changes are
possible.
SYMBOL
DESCRIPTION
Device in Patient menu. Expert menu locked.
Expert menu enabled.
Indicates respiratory status:
• Arrow pointing upward: Inspiration
• Arrow pointing downward: Exhalation
• S: Spontaneous breath
• T: Mandatory breath
Device set for adults.
Leakage circuit set.
Single circuit with valve set.
Double circuit set.
Battery charging. If the gray area reaches the
top, the battery is fully charged.
Battery capacity high, battery discharging.
Battery capacity medium, battery discharging.
Battery capacity low, battery discharging.
Battery capacity low.
Battery fault
Filter change (only if function is activated).
Service reminder function (only if function is
activated).
SpO
2
sensor:
Gray: Not connected
Green: Connected and high signal quality
Yellow: Connected and moderate signal
quality
Red: Connected and poor signal quality
FiO
2
cell
Green: Activated and full
Gray: Activated and empty
Green and flashing: Calibration process in
progress
Patient monitor connected.
Green: USB flash drive connected.
Gray: USB flash drive faulty.
Low-priority alarm triggered.
Medium-priority alarm triggered.
High-priority alarm triggered.
All physiological alarms have been
deactivated.
Acoustic signal for alarm paused.
PART
DESCRIPTION
VENTI
remote
alarm
For remote transmission and display
of the alarm signals output by the
device
SpO
2
sensor
Determines SpO
2
and pulse
frequency data
Breathing system
filter
Prevents the transmission of particles
and microorganisms to the breathing
system
FiO
2
cell
Performs permanent FiO
2
measurement
Circuit
Supplies the patient with respiratory
air
Exhalation valve
Routes exhaled air into the
environment
External battery
Serves as an additional external
energy supply for the device
Protective bag for
LUISA
Serves to transport and store the
device with protection
Follow the instructions for use for the accessories.
Here you will find further information about
operation and combining accessories with the device.
SYMBOL
DESCRIPTION