background image

 

 

  Code: MSGB202$0500.doc                                       18/06/2004                                                                       P.  15 / 20

 

 
 
At the time of initial installation, the password is 

LOVATO

. You can record a new, personalized password 

subsequently, clicking on the 

New password

 button and then entering the new password you have chosen 

twice consecutively. 

 

Fig. 8.2 – New password 

 
 

 

 
 

 

Communication menu 

 

Online 

The 

Communication-Online

 menu allows to re-establish the serial link after it has been stopped by the user 

with the Offline command. When clicking Online, the software executes a complete scan of all configured 
DMK, to verify their status. 
 
 

Offline 

With communication-Offline the user has the possibility to temporarily suspend the serial communication link 
between the PC and the DMK network.  
This command is to be used when, for instance, it is necessary to modify the network wiring or when DMK 
are to be switched off. The System Offline status is displayed on the main page Toolbar (at the bottom of the 
main window).  
The system passes automatically in Offline mode when the user opens the 

Configuration

 window. 

 
 

Modem Call 

To connect to one or several DMK via a couple of modems, it is necessary to select the Modem connection 
checkbox in the 

Configuration-Options-General

 window. Selecting modem communication will automatically 

change the communication protocol used by the software, from the standard Modbus RTU to Modbus ASCII, 
which can be used with modems.  From the user point of view, the difference between those two protocols is 
only a little slower speed in case of the ASCII protocol, due to its length that is double than the RTU and the 
modem modulation that requires also a certain amount of time. 
When the program is configured for modem communication (see 

Configuration-Options-General

 window) it 

automatically shows the modem call dialog after it has been started, because it is not possible to 
communicate with the DMK before dialing the phone number of the remote modem.  The same window can 
be opened manually using 

Communication-Modem call

 menu or the dedicated pushbutton on the toolbar. 

 

Figure 8.3 - Communication-Modem call 

 

 

Содержание DMK40

Страница 1: ...n diagram direct 3 Basic principles 5 Main window 5 System configuration 6 Important note 9 Display menu 10 Data collection 10 Graphs 11 Front panel 14 Password 14 Communication menu 15 Online 15 Offl...

Страница 2: ...and be familiar with Windows operating system commands The software is delivered on a CD with two different installation procedures The standard installation procedure used with the first releases of...

Страница 3: ...onverter as indicated in the Connection diagrams paragraph below Comply scrupulously with the polarity of the Rs485 cables 4 We recommend use of a Rs232 Rs485 converter furnished by Lovato If you inte...

Страница 4: ...Serial port settings window while for the DMK it is selected with parameter P 42 see Addendum The connection polarity of the DMKs and of the converter to the RS 485 bus must be correct all the A term...

Страница 5: ...vidual measurement can be displayed and printed Main window The main window of the program contains all the menus and the toolbars for access to the various functions As they may modify the configurat...

Страница 6: ...ystem configuration is a very important phase as regards definition of software functioning In particular if several multimeters are connected attention must be paid to programming the parameters of e...

Страница 7: ...op If the selected measure indicates all three phases it is sufficient the measure value of one of the three phases is greater than threshold 1 to trigger the datalogger The same procedure is done to...

Страница 8: ...ntly saved record is lost Transmits the settings made Note on transmitting the settings all the data saved in the DMK40 will be lost Receives the settings saved in the DMK40 View the DMK real time clo...

Страница 9: ...figure 2 2 When using modem connection all this setting can be used only if the remote connection is done always to the same DMK network that is if there is only one record in the Modem index because...

Страница 10: ...th the Display Data collection menu or clicking on the matching icon on the toolbar Fig 3 1 Display Data collection Sampling date and time Number of records selected Values of the variables sampled Di...

Страница 11: ...aph menu or click on the matching icon of the toolbar This type of graph is very similar to t hat of an oscilloscope The time is indicated on the X horizontal axis The horizontal time scale is common...

Страница 12: ...Code MSGB202 0500 doc 18 06 2004 P 12 20...

Страница 13: ...Code MSGB202 0500 doc 18 06 2004 P 13 20...

Страница 14: ...d or holding down of the keys Note The quality of the graphic representation of the front panel may vary according to the graphic resolution of your PC and or the monitor settings used Fig 7 1 Display...

Страница 15: ...dow The system passes automatically in Offline mode when the user opens the Configuration window Modem Call To connect to one or several DMK via a couple of modems it is necessary to select the Modem...

Страница 16: ...shaking messages with the answering modem At the end of this procedure if everything has been carried out correctly the PC status bar will show a message informing the user that connection has taken p...

Страница 17: ...the DMK The following four menus are available Basic setup basic settings such as CT VT ratio etc Advanced setup settings of the digital outputs Capacitor overload setup parameters relating to the ca...

Страница 18: ...eful when programming a set of multimeters with the same settings or when you want to file the original settings of a system To save the parameters on disk select the Parameters Save to file menu and...

Страница 19: ...r the confirmation message and then disconnect the modem from the PC and connect it to the DMK The PM EXE program transmits the following configuration string to the modem AT E0 N6 U6 W0 CR commands v...

Страница 20: ...below Click on Dial At this point the modem at the PC end calls the DMK modem After a few rings the DMK modem and the program switch automatically to the online mode To end the connection choose Modem...

Отзывы: