background image

 

 

  Code: MSGB202$0500.doc                                       18/06/2004                                                                       P.  10 / 20

 

 
 
 
 
 
 
 
 
 

Display menu 

Data collection 

The variables defined in the 

Data collection

 configuration page (Fig. 2.3) are unloaded from the multimeter 

by pressing the ‘Start Rx data’ key. The same data are saved in an Ms-Access format database. 
The data collected can be displayed in table form with the 

Display-Data collection

 menu or clicking on the 

matching icon on the toolbar.  
 

Fig. 3.1 – Display-Data collection 

 
 
 
 
 

 

 
 

 
 
 
 
 

  
 
 
 
 
 
 
 

Sampling date 
and time 

Number of 
records selected 

Values of the 
variables sampled

Display period 
selected. Extracts the 
values within a 
specific interval of 
time from the 
database. 

Opens the window for 
specification of the interval of 
time to be selected 

Displays all 
the record of 
the database 

Permits export of 
the data selected 
in ASCII or Excel 
text files 

Deletes the 
data selected 
from the 
database 

Содержание DMK40

Страница 1: ...n diagram direct 3 Basic principles 5 Main window 5 System configuration 6 Important note 9 Display menu 10 Data collection 10 Graphs 11 Front panel 14 Password 14 Communication menu 15 Online 15 Offl...

Страница 2: ...and be familiar with Windows operating system commands The software is delivered on a CD with two different installation procedures The standard installation procedure used with the first releases of...

Страница 3: ...onverter as indicated in the Connection diagrams paragraph below Comply scrupulously with the polarity of the Rs485 cables 4 We recommend use of a Rs232 Rs485 converter furnished by Lovato If you inte...

Страница 4: ...Serial port settings window while for the DMK it is selected with parameter P 42 see Addendum The connection polarity of the DMKs and of the converter to the RS 485 bus must be correct all the A term...

Страница 5: ...vidual measurement can be displayed and printed Main window The main window of the program contains all the menus and the toolbars for access to the various functions As they may modify the configurat...

Страница 6: ...ystem configuration is a very important phase as regards definition of software functioning In particular if several multimeters are connected attention must be paid to programming the parameters of e...

Страница 7: ...op If the selected measure indicates all three phases it is sufficient the measure value of one of the three phases is greater than threshold 1 to trigger the datalogger The same procedure is done to...

Страница 8: ...ntly saved record is lost Transmits the settings made Note on transmitting the settings all the data saved in the DMK40 will be lost Receives the settings saved in the DMK40 View the DMK real time clo...

Страница 9: ...figure 2 2 When using modem connection all this setting can be used only if the remote connection is done always to the same DMK network that is if there is only one record in the Modem index because...

Страница 10: ...th the Display Data collection menu or clicking on the matching icon on the toolbar Fig 3 1 Display Data collection Sampling date and time Number of records selected Values of the variables sampled Di...

Страница 11: ...aph menu or click on the matching icon of the toolbar This type of graph is very similar to t hat of an oscilloscope The time is indicated on the X horizontal axis The horizontal time scale is common...

Страница 12: ...Code MSGB202 0500 doc 18 06 2004 P 12 20...

Страница 13: ...Code MSGB202 0500 doc 18 06 2004 P 13 20...

Страница 14: ...d or holding down of the keys Note The quality of the graphic representation of the front panel may vary according to the graphic resolution of your PC and or the monitor settings used Fig 7 1 Display...

Страница 15: ...dow The system passes automatically in Offline mode when the user opens the Configuration window Modem Call To connect to one or several DMK via a couple of modems it is necessary to select the Modem...

Страница 16: ...shaking messages with the answering modem At the end of this procedure if everything has been carried out correctly the PC status bar will show a message informing the user that connection has taken p...

Страница 17: ...the DMK The following four menus are available Basic setup basic settings such as CT VT ratio etc Advanced setup settings of the digital outputs Capacitor overload setup parameters relating to the ca...

Страница 18: ...eful when programming a set of multimeters with the same settings or when you want to file the original settings of a system To save the parameters on disk select the Parameters Save to file menu and...

Страница 19: ...r the confirmation message and then disconnect the modem from the PC and connect it to the DMK The PM EXE program transmits the following configuration string to the modem AT E0 N6 U6 W0 CR commands v...

Страница 20: ...below Click on Dial At this point the modem at the PC end calls the DMK modem After a few rings the DMK modem and the program switch automatically to the online mode To end the connection choose Modem...

Отзывы: