  Code: MSGB202$0500.doc                                       18/06/2004                                                                       P.  16 / 20

 

Once the window illustrated has been opened, from the pull-down box choose the name of the installation 
with which you want to be connected. The names entered in the 

Modem index 

during configuration will be 

displayed. Once the choice has been made, the corresponding phone number appears in the box below. 
Click the 

Dial 

button to start the connection procedure. 

At this point the program will instruct the modem to make the call. While waiting, the sliding blue bar of the 
maximum time allowed for making the connection will be seen (1 minute).  The modem called will take the 
line and exchange the usual handshaking messages with the answering modem. At the end of this 
procedure, if everything has been carried out correctly, the PC status bar  will show a message informing the 
user that connection has taken place and the program will switch automatically to the 

Online 

mode.  If any 

errors occur, carefully check the connections and if necessary follow the 

Troubleshooting guide 

given in 

appendix A of this manual. Normally connection is not critical since very common and absolutely standard 
procedures are used. With the 

Break 

button it is possible to block the calling procedure, while 

Hang up 

ends 

a communication already in progress. 
 

Hang up 

This command interrupts a modem connection, closing the telephone line. It is the equivalent of hanging up 
the handset in an ordinary phone call. It is carried out automatically every time you exit the program. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание DMK40

Страница 1: ...n diagram direct 3 Basic principles 5 Main window 5 System configuration 6 Important note 9 Display menu 10 Data collection 10 Graphs 11 Front panel 14 Password 14 Communication menu 15 Online 15 Offl...

Страница 2: ...and be familiar with Windows operating system commands The software is delivered on a CD with two different installation procedures The standard installation procedure used with the first releases of...

Страница 3: ...onverter as indicated in the Connection diagrams paragraph below Comply scrupulously with the polarity of the Rs485 cables 4 We recommend use of a Rs232 Rs485 converter furnished by Lovato If you inte...

Страница 4: ...Serial port settings window while for the DMK it is selected with parameter P 42 see Addendum The connection polarity of the DMKs and of the converter to the RS 485 bus must be correct all the A term...

Страница 5: ...vidual measurement can be displayed and printed Main window The main window of the program contains all the menus and the toolbars for access to the various functions As they may modify the configurat...

Страница 6: ...ystem configuration is a very important phase as regards definition of software functioning In particular if several multimeters are connected attention must be paid to programming the parameters of e...

Страница 7: ...op If the selected measure indicates all three phases it is sufficient the measure value of one of the three phases is greater than threshold 1 to trigger the datalogger The same procedure is done to...

Страница 8: ...ntly saved record is lost Transmits the settings made Note on transmitting the settings all the data saved in the DMK40 will be lost Receives the settings saved in the DMK40 View the DMK real time clo...

Страница 9: ...figure 2 2 When using modem connection all this setting can be used only if the remote connection is done always to the same DMK network that is if there is only one record in the Modem index because...

Страница 10: ...th the Display Data collection menu or clicking on the matching icon on the toolbar Fig 3 1 Display Data collection Sampling date and time Number of records selected Values of the variables sampled Di...

Страница 11: ...aph menu or click on the matching icon of the toolbar This type of graph is very similar to t hat of an oscilloscope The time is indicated on the X horizontal axis The horizontal time scale is common...

Страница 12: ...Code MSGB202 0500 doc 18 06 2004 P 12 20...

Страница 13: ...Code MSGB202 0500 doc 18 06 2004 P 13 20...

Страница 14: ...d or holding down of the keys Note The quality of the graphic representation of the front panel may vary according to the graphic resolution of your PC and or the monitor settings used Fig 7 1 Display...

Страница 15: ...dow The system passes automatically in Offline mode when the user opens the Configuration window Modem Call To connect to one or several DMK via a couple of modems it is necessary to select the Modem...

Страница 16: ...shaking messages with the answering modem At the end of this procedure if everything has been carried out correctly the PC status bar will show a message informing the user that connection has taken p...

Страница 17: ...the DMK The following four menus are available Basic setup basic settings such as CT VT ratio etc Advanced setup settings of the digital outputs Capacitor overload setup parameters relating to the ca...

Страница 18: ...eful when programming a set of multimeters with the same settings or when you want to file the original settings of a system To save the parameters on disk select the Parameters Save to file menu and...

Страница 19: ...r the confirmation message and then disconnect the modem from the PC and connect it to the DMK The PM EXE program transmits the following configuration string to the modem AT E0 N6 U6 W0 CR commands v...

Страница 20: ...below Click on Dial At this point the modem at the PC end calls the DMK modem After a few rings the DMK modem and the program switch automatically to the online mode To end the connection choose Modem...

Отзывы: